Electric Heat Brochure

Page 24
1
Sizes 23 and 25 MUST be ordered in pairs to minimize shipping damage.
2
Units with Option AK3E (240V supply voltage) can be connected to 208V power supply, heating capacity will be reduced by 25%.
3
High-limit temperature control is based on elevation.
4
"Off" position.
Other voltages available upon request.
EBHB
Size 3 5 8 10 13 15 18 20 23
1
25
1
Heating Capacity
Watts
300 500 750 1000 1250 1500 1750 2000 2250 2500
BTUH
10 17 26 34 51 68 85
Length
in.
22-3/4 27-3/4 37-3/4 48 60 72 75-1/2 96 93 102-1/4
mm
577 702 956 1217 1524 1829 1916 2439 2364 2596
Ship Weight
Lbs
4.5 5.4 7.0 8.7 10.7 12.7 13.2 16.6 16.2 17.8
Kg
2.0 2.4 3.2 3.9 4.9 5.7 6.0 7.5 7.3 8.0
Factory Installed Options
Supply Voltage/
Phase
120/1
AK1E
208/1
AK15
240/1
2
AK3E
Cabinet Color
White
HK1
Almond
HK2
Special Color
SPEC
Call for availability
High-limit
Temperature
Control
3
Up to 6,000 ft
AB15
3,000 to 8200 ft
AB16
Control Voltage
120V, 208V, 240V
STD
24V Relay
BT1
Field Installed Options (shipped separately)
Size 3 5 7 10 13 15 18 20 23
1
25
1
Wall Mounted
Thermostat
Light duty line voltage thermostat; single-pole,
single-throw
CL5L
Light duty line voltage thermostat; double-pole,
single-throw
CL5D
Unit Mounted
Thermostat
Single-pole, bimetal thermostat
IT14
Double-pole, bimetal thermostat
4
IT15
Single-pole, bimetal, tamper-proof thermostat
IT16
Double-pole, bimetal, temper-proof thermostat
4
IT17