Parts Manuals User guide

Form P-SC, P/N 269822R3, Page 13






Codes 162-174 - FM,
Option BM14 (applies to
Model Series SSCBL)
Code 138, 153, 166 - Pilot
Valve Bracket in Options
BM12, BM13, BM14,
P/N 100262
146
144
148
144
145
146
146
Branch Tee, P/N 96809
146
Settings
Natural 4
Propane 9
Vent Pipe
Branch Tee, P/N 96809
Codes 144-161 - IRI, Option BM13 (applies to Model SSCBL 1050 and 1200) - DISCONTINUED 9/2003
Codes 136, 137, 149, 165 -
Solenoid Valve
Code 148 - Vent
Valve, G/C #S262,
P/N 86996
Codes 155 and 167 - Pilot
Regulator, Maxitrol R400S,
P/N 86965
P/N 86993 Actuator
(M/H V4055A1007)
Codes 144 and 162
1/4", P/N 25787
3/4", P/N 88242
1", P/N 112922
Code Description P/N Code Description P/N
Components for IRI Manifold (Option BM13)
144
Fluid Power Valve (2)89356
154
Transformer 230/460 to 115V, .5KVA 86997
Fluid Power Valve Actuator (2)86993 Transformer 208 to 115V, .5KVA 86998
145 Low Gas Pressure Switch, pg 6, Code 41 or 42. Transformer 208 to 115V, 250VA 86991
146 High Gas Pressure Switch, page 6, Code 43. Transformer 230/460/575 to 115V, 300VA 105202
147 Vent Limiter, Maxitrol A1209, pg 6 (2)123481 155 Pilot Regulator (3)86965
148 Vent Solenoid Valve 86996 156 Valve Box Top 110194
149 Pilot Valve (one per unit) 25787 157 Valve Box Inlet Side 110195
150 Manual Shutoff & Ball Valve Adapter, page 11 158 Valve Box Plain Side 110196
151 Pilot Manual Shutoff (1 per unit), page 11 159 Valve Box Back 110197
152
RBM Relay - Order Replacement Kit,
P/N 263527.
160 Top Door 110198
153 Pilot Valve Bracket (2)100262 161 Bottom Door 110199
Code Description P/N
Components for FM Manifold (Option BM14 is available on
Model SSCBL)
162
Fluid Power Valve 89356
Fluid Power Valve Actuator 86993
163 Manual Shutoff and Ball Valve Adapter, page 11
164 Pilot Manual Shutoff (one per unit), page 11
165 Pilot Valve (one per furnace) 25787
166 Pilot Valve Bracket 100262
167 Pilot Regulator 86965
168
Transformer 230/460/575 to 115V, 300VA 105202
Transformer 208 to 115V, 250VA 86991
169 Valve Box Top 110211
170 Valve Box Inlet Side 110195
171 Valve Box Plain Side 110196
172 Valve Box Back 110212
173 Top Door 110213
174 Bottom Door 110214
Springs for R400S Pilot Regulator
Maxitrol # Color Pressure Range Approx Length.
R400B10-13 Brown 1.0 to 3.5" w.c. 1-9/16 to 2"
R400B10-25 Cadmium Plate 2.0 to 5.0" w.c. 1-9/16 to 2"
R400B10-36 Cadmium Plate 3.0 to 6.0" w.c. 1-9/16 to 2"
R400B10-38 Pink 3.0 to 8.0" w.c. 1-9/16 to 2"
Valve only (used with actuator on the right)
Size Gas Reznor M/H
1" N or P 86992 V5055A1004
1-1/4" N or P 89356 V5055A1012
2" N or P 91079 V5055A1038
Replacement Motors (Tables on pages 14-16)
Motors in the Open, TEFC, and Premium Efciency tables
that are highlighted in gray do not have internal overload
protection and must be used with the motor starter and
overload listed in the table. Refer to the wiring diagram for
applicable AL and AN or VFD option codes.
See Code 36, page 6, for standard motor contactor (Option
AN2), P/N 216386, for motors with internal overloads.
If equipped with an optional variable frequency drive, see
P/N's on the right.
Replacement Blower Motors, Starters, and Variable Frequency Drives
IEC
Adjustable
Overload
IEC Starter
(Contactor)
Variable
Frequency Drive
(Option VFD) and
Matching Line
Reactor
Mtr
HP
VFD Drive
& Matching
Line Reactor
208/1/60
230/1/60
208/3/60
230/3/60
480/3/60 575/3/60
ODP TEFC ODP TEFC Prem ODP TEFC Prem ODP TEFC
Prem
1/2
Drive 221600 221605 N/A 221612 N/A
N/A
Line Reactor 221595 221598 221590
3/4
Drive
N/A
221606 N/A 221613 N/A
N/A
Line Reactor 221598 221591
1
Drive 221601 221607 221614
N/A
Line Reactor 221596 221594 221592
1-1/2
Drive 221602 221608 221615
N/A
Line Reactor 221597 221595 221593
2
Drive 221603 221609 221616 221855
Line Reactor 221597 221596 221585 NA (Built-in)
3
Drive 221604 221610 221617 221856
Line Reactor 221599 221597 221586 NA (Built-in)
5
Drive
N/A
221611 221618 221857
Line Reactor 221599 221587 NA (Built-in)
Replacement
IEC Starters and
Overloads (Listed by
motor on pages 14-16.)
When ordering a
replacement IEC starter
(contactor) or overload,
check the manufacturer's
number on both parts. If the number is different than that
listed, both components must be replaced. IEC Starter
(contactor) and overload are mounted on rail, P/N 111387.
Replacement holding coils are listed on page 17.
If the motor has a NEMA starter, see replacement
information on page 16.