® UNIT HEATER CATALOG COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS FUEL Natural Gas Propane Fuel Oil CAPACITIES 25 - 1,200 MBH 80% - 93% Thermal Efficiency 380 - 16,750 CFM AIR DELIVERY Propeller Fan Centrifugal Blower (Ductable) Visit www.RezSpec.com for more information.
BACKGROUND PRODUCT SCOPE Reznor was founded in 1888 to manufacture the “Reznor” reflector heater, which used a luminous flame gas burner developed by George Reznor. This technological breakthrough was an immediate success and hastened the expansion of gas heating in residential and commercial applications. Technological development and innovation have been the hallmark of Reznor products through the years.
Page Number _______ of ______ Unit Heater Catalog Contents Model UEAS Model UDAP Model F Model LDAP Model UEAS....................................................................................................... 2 DESCRIPTION........................................................................................ 2 TECHNICAL DATA.................................................................................. 3 DIMENSIONS...............................................................................
Page Number _______ of ______ Super High Efficiency Separated Combustion, Low Static Unit Heaters for Commercial/ Industrial Use DESCRIPTION Model UEAS Reznor® V3 Series Model UEAS gas-fired, high efficiency, separated combustion unit heaters are available in 4 sizes ranging from 131,000 to 305,000 BTUH gas input.
Page Number _______ of ______ ACCESSORIES - FIELD INSTALLED ●● Horizontal or vertical combustion air/vent kit including concentric adapter B ●● Thermostat ●● Thermostat guard with locking cover ●● Vertical louvers ●● Downturn nozzle kits ●● Manual shutoff valves B Selection of either a horizontal or vertical combustion air/vent kit is required.
Page Number _______ of ______ DIMENSIONS Model UEAS ±1/16" (2mm) Disconnect Switch G F Line Voltage Entrance (connects in sealed electrical box) R 5-5/8” (143mm) External Gas Connection 1-9/16” (40mm) Rear View Top View E Four Suspension Points 25” (635mm) P 6” Combustion Air Connection (3/8-16 Female Thread) S 8-1/4” (210mm) 3-1/4” (83mm) N M Thermostat Connection B 23” (584) A Condensate Drain 4” Vent Connection K H J 1-1/4” (32mm) C LED Viewport Front View Size A B Dimension
Page Number _______ of ______ Separated Combustion, Low Static Commercial/Industrial Unit Heaters Model UDAS DESCRIPTION CSA 2.6b Sizes 30-125 carry an additional approval for use in residential garage/workshops under CSA International Requirement 10.96 - U.S. and CR96-0005 - Canada ANSI Z83.
Page Number _______ of ______ OPTIONAL FEATURES FACTORY INSTALLED ●● Single-stage, propane gas valve (field adjustable for operation to 9,000 ft.
Page Number _______ of ______ DIMENSIONS Model UDAS ±1/16" (2mm) Size 30, 45 60 75 100 125 A 12 1/8 15 1/8 15 1/8 23 1/8 23 1/8 B 26 5/8 26 5/8 26 5/8 26 5/8 26 5/8 C 10 13 13 21 21 13 13 13 13 13 D 13/16 13/16 13/16 13/16 13/16 E 26 27 27 5/8 28 5/8 29 3/8 21 21 21 21 21 F 9/16 9/16 9/16 9/16 9/16 G 5 3/16 7 7/8 7 7/8 14 1/2 14 1/2 6 6 6 6 6 H 1/2 1/2 1/2 1/2 1/2 J 2 11/16 5 1/2 5 1/2 8 3/4 8 3/4 3 3 3 3 3 K 7/8 7/8 7/8 7/8 7/8 M 17 3/8 17 3/8 17 3/8 17 3/8 17 3/8 N 11/16 11/16 11/16 11/16
Page Number _______ of ______ Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters Model UDAP DESCRIPTION CSA 2.6b Sizes 30-125 carry an additional approval for use in residential garage/workshops under CSA International Requirement 10.96 - U.S. and CR96-0005 - Canada ANSI Z83.
Page Number _______ of ______ OPTIONAL FEATURES FIELD INSTALLED ●● Vent cap ●● Thermostat ●● Thermostat guard with locking cover ●● Vertical louvers ●● Downturn nozzle kits ●● Gas conversion kits (natural and propane) ●● Primary/secondary controls for zoning up to six units ●● Ceiling suspension kit - Sizes 30-125 ●● Hanger kits for 1” pipe ●● Stepdown transformer (for 208/115, 230/115 or 460/115 supply voltage) ●● Manual shutoff valves TECHNICAL DATA Model UDAP Size Input Heating Capacity BTUH kw/h Th
Page Number _______ of ______ DIMENSIONS Model UDAP ±1/16" (2mm) Size 30, 45 60 75 100 125 A 12 1/8 15 1/8 15 1/8 23 1/8 23 1/8 B 25 5/8 25 5/8 25 5/8 25 5/8 25 5/8 C 10 13 13 21 21 150, 175, 200 20 1/8 38 3/16 16 23 13 13 13 13 13 D 13/16 13/16 13/16 13/16 13/16 E 26 27 27 5/8 28 5/8 29 3/8 F 9/16 9/16 9/16 9/16 9/16 G 5 3/16 7 7/8 7 7/8 14 1/2 14 1/2 6 6 6 6 6 H 1/2 1/2 1/2 1/2 1/2 J 2 11/16 5 1/2 5 1/2 8 3/4 8 3/4 3 3 3 3 3 42 35 3/8 8 1/2 8 1/4 5 7/16 21 21 21 21 21 K 7/8 7/8 7/
Page Number _______ of ______ DESCRIPTION CSA 2.6b Separated Combustion, High Static Blower Type Unit Heaters for Commercial/Industrial Use Model UDBS ANSI Z83.8b Reznor® V3 Series Model UDBS gas-fired separated combustion unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input.
Page Number _______ of ______ OPTIONAL FEATURES FACTORY INSTALLED ●● Equipped for propane gas ●● Single-stage, propane gas valve (field adjustable for operation to 9,000 ft. elevation B) ●● Two-stage natural gas or propane gas valve - Sizes 60-400 ●● 409 or 316 Stainless steel heat exchanger ●● 208, 230, 480, and 575 Three phase voltage - Sizes 150-400 (step down transformer shipped separate for field installation for 480 and 575 units) ●● Adjustable belt drive and motor for up to .5” w.c.
Page Number _______ of ______ DIMENSIONS Combustion Air Collar (see Technical Data for size) Thermostat Connection (30-45 horizontal: 60-400 vertical) Model UDBS ±1/16" (2mm) L M N P K** TOP VIEW J Vent Connection (see Technical Data for size) 1/2” NPT External Gas Connection Q R S G 3/8” - 16 Female Thread - four suspension points in Hanger Bars REAR VIEW Direct Drive Blower attached to the Cabinet - Sizes 30-75 H** Hanger Bar Direct Drive Blower with Blower Back on the Cabinet -Sizes 100
Page Number _______ of ______ Power Vented, High Static Blower Type Unit Heaters for Commercial/Industrial Use DESCRIPTION CSA 2.6b Model UDBP ANSI Z83.8b Reznor® V3 Series Model UDBP gas-fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input.
Page Number _______ of ______ OPTIONAL FEATURES FIELD INSTALLED ●● Vent cap ●● Thermostat ●● Thermostat guard with locking cover ●● Vertical louvers ●● Downturn nozzle (30° or 60° deflection, with and without vertical louvers) ●● Gas conversion kits (natural and propane) ●● High altitude kits (above 6,000 ft. to 9,000 ft.
Page Number _______ of ______ DIMENSIONS Model UDBP ±1/16" (2mm)
MODEL F Gas-Fires, Gravity-Vented, Fan-Type Unit Heater for Commercial/Industrial Use Page Number _______ of ______ WARNING: Gas-fired appliances are not designed for use in hazardous atmospheres containing flammable vapors or combustible dust, or atmospheres containing chlorinated or halogenated hydrocarbons.
Page Number _______ of ______ TECHNICAL DATA Model F Size Heating Input - BTUH (kW) Thermal Output - BTUH (kw) (80%) A Vent Outlet Diameter Gas Connection - Natural Gas B Control Amps (24-volt) Full-Load Amps (115 volt) Normal Consumption (watts) Throw at 8’ (2.4M) Mntg Ht - ft (M) C Standard Motor HP D Optional Enclosed Motor RPM Fan Diameter - in. (mm) Air Volume - CFM (M3/hr) Outlet Velocity - FPM (M/s) Approximate Net Wt - lbs (kg) Approximate Shipping Wt - lbs (kg) 25 25,000 (7.3) 20,000 (5.
Page Number _______ of ______ DIMENSIONS Model F ±1/16" (2mm) Size 25,50 75 100 125 165 200 250 300 400 in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) A 30 1/8 (765) 30
Page Number _______ of ______ DESCRIPTION ANSI Z83.8 MODEL B Gas-Fired, Gravity-Vented, Blower-Type Unit Heater for Commercial/Industrial Use CAN/CGA 2.6 WARNING: Gas-fired appliances are not designed for use in hazardous atmospheres containing flammable vapors or combustible dust, or atmospheres containing chlorinated or halogenated hydrocarbons.
Page Number _______ of ______ OPTIONAL FEATURES FIELD INSTALLED ●● Power venter ●● Vertical louvers ●● Downturn air nozzle, 25-65° or 50-90° variable air deflector range ●● Thermostat and relay kits ●● Air recirculation kits ●● Manual summer/winter switch ●● Filter cabinet with 1" or 2" filters ●● Polytube adapter - Models 75-400 ●● Multiple heater control ●● Hanger kits to suspend from 1" pipe or to use with vibration isolation suspension ●● Unit-mounted thermostat bracket ●● Step down transformer 230/11
Page Number _______ of ______ DIMENSIONS H Model B (4) SUSPENSION POINTS 3/8 - 16 FEMALE THREADS (Centerlines) ±1/16" (2mm) P N B G C N 13/16” (21mm) ELECTRIC SUPPLY CONNECTION (Centerline) RIGHT SIDE OPTIONAL VERTICAL POSITION X 13/16” (21mm) 3/4” (19mm) Y E S U F V B÷2 J = VENT SIZE 12-1/4” (57mm) 3/4” (19mm) NOTE J A R Z K NO TE L OPTIONAL BLOWER CABINET Size 25 50 75 100 125 165 200 250 300 400 in mm in mm in mm in mm in mm in mm in mm in A 30 1/8 (765) 30 1/8 (765) 30
Page Number _______ of ______ Oil-Fired, Fan-Type, Unit Heater DESCRIPTION ® MODEL OH The Model OH Series oil-fired unit heaters is available in inputs of 118,000, 173,000, and 229,000 BTUH with 82% efficiency output. These completely packaged unit heaters burn No. 2 fuel oil. Model OH heaters are equipped with a propeller fan.
Page Number _______ of ______ TECHNICAL DATA Size Thermal Input - BTUH (kW) Thermal Output - BTUH (kW) Nozzle Input - GPH (l/hr) Full-Load Amps (115 volt) Fan Motor RPM Blower Motor RPM Motor HP Air Volume (Free Air) - CFM (M3/hr) Air Volume @ .25” ESP - CFM (M3/hr) Throw at 9’ (3M) Mntg Ht - ft (M) Flue Diameter - inches Blower Size - inches Fan Diameter (inches) and Pitch (°) Approximate Net Wt (lbs) Approximate Shipping Wt Model OH OH95 OH140 OH190 118,000 (34.6) 173,000 (50.7) 229,000 (67.
Page Number _______ of ______ Indirect Fired, Indoor, Downflow, Packaged Heater Model LDAP All Model LDAP high bay packaged heaters are design certified by ETL for use in industrial and commercial installations. These heaters must be installed in accordance with local building codes.
TECHNICAL DATA Page Number _______ of ______ Model LDAP Size Input Heating Capacity Thermal Efficiency (%) Output Heating Capacity Gas Connection (Inches) Vent Connection Diameter (Inches) Control Amps (24 volt) Full Load Amps (208 volt) Full Load Amps (230 volt) Normal Power Consumption @ 208V (watts) Normal Power Consumption @ 230V (watts) Discharge Air Temperature Rise (°F) Air Volume Discharge Air Opening Area Outlet Velocity Air Volume (Destratification @ Medium Speed) Outlet Velocity (Destratificatio
Page Number _______ of ______ DIMENSIONS Model LDAP 800 and 1200 Model LDAP 1200 is illustrated. Model LDAP 800 has two heat sections. Model LDAP 800 is the same as the layout shown without the middle section.
Page Number _______ of ______ Throw/Floor Coverage H X Y Z Size Mounting Height 8 10 12 14 16 18 Applies to both Model UDAS and Model UDAP Dimension in feet Mounting Height 5 8 10 12 14 16 18 Size Height measured from the floor to the bottom of the unit heater. Point where heated air from the heater reaches the floor. Point where heated air tends to rise from the floor. Point where the air velocity drops below 50 feet per minute (254 mm/sec).
Page Number _______ of ______ Throw/Floor Coverage (cont'd) Applies to both Model UDBS and Model UDBP See illustration on previous page.
Page Number _______ of ______ Throw/Floor Coverage (cont'd) Applies to both Model UDBS and Model UDBP See illustration on page 25. Dimension in metric Low Speed Size Mounting Height X 1.5 2.1 2.4 2.1 3.0 2.1 3.7 -4.3 -4.9 -5.5 -Size Mounting Height 1.5 2.4 3.0 3.7 4.3 4.9 5.5 Size Mounting Height 1.5 2.4 3.0 3.7 4.3 4.9 5.5 30 Y 4.6 4.0 3.4 ----- Louver Angle -27° -44° -56° ----- X 2.1 2.7 2.7 2.7 ---- Y 5.2 5.2 4.9 4.3 ---- 30 X 2.1 2.7 2.4 2.4 ---- Y 4.9 4.9 4.3 3.7 ---- Z 13.1 11.6 10.1 8.
Page Number _______ of ______ Throw/Floor Coverage (cont'd) Applies to Model F Sizes 125-400 Height measured from the floor to the bottom of the unit heater. Point where heated air from the heater reaches the floor. Y Point where heated air tends to rise from the floor. Z Point where the air velocity drops below 50 feet per minute (254 mm/sec). NOTES: Data based on 80°F entering air and 60°F rise through the unit.
Page Number _______ of ______ Throw/Floor Coverage (cont'd) Applies to Model B Sizes 125-400 Floor Coverage with 50-90 degree Variable Air Deflection Downturn Nozzle Blower Model 125 165 200 250 300 400 KEY: CFM 1545 2090 2470 3090 3710 4950 Blower Model M3/hr 125 2625 165 3551 200 4196 250 5250 300 6303 400 8410 A = Throw B = Spread (Side to side coverage with standard louvers) H = Mounting Height 12 A 20 24 ----- ft B 22 26 ----- 3.7M A B 6.1 6.7 7.3 7.
Page Number _______ of ______ Sound Data Sound (in dBA) for Models UDAP and UDAS at various distances. Size 30 45 60 75 100 125 150 175 200 225 250 300 350 400 5 Feet 1.5 meters 59 59 59 69 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A 10 Feet 3.0 meters 47 47 47 55 58 59 55 55 56 59 59 62 64 65 15 Feet 4.6 meters 40 40 40 49 54 55 51 52 53 56 56 59 61 62 Sound (in dBA) for Models UDBP and UDBS at a distance of 15 feet (4.6 meters).
Page Number _______ of ______ BLOWER CHARTS Models UDBP and UDBS Blower Chart for Sizes 150 - 400 Standard motor and drive shown shaded. UDBP and UDBS 150 175 200 225 250 300 350 400 Nozzle Option with Louvers TEMP RISE °F CFM 45o 30o EXTERNAL Static Pressure 60o 0” .25” .50” RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 2562 730 0.43 730 0.43 730 0.43 840 0.55 930 0.68 60o 1921 520 0.25 520 0.25 520 0.25 655 0.35 780 0.43 75o 1537 405 0.17 405 0.
Page Number _______ of ______ BLOWER CHARTS Model B with Belt Drive Motor (cont'd) Optional Blower/Filter Cabinet for Models B ●● Shipped separately for field assembly and installation ●● Filter Rack (less filters) ●● Filter Rack with 1" or 2" Permanent Filters (3) Key to Drive Options AM1 401-450 RPM AM6 651-700 RPM AM10 851-900 RPM AM14 1051-1100 RPM AM2 451-500 RPM AM7 701-750 RPM AM11 901-950 RPM AM15 1101-1150 RPM AM3 501-550 RPM AM8 751-800 RPM AM12 951-1000 RPM AM16 1151
Page Number _______ of ______ MOTOR FULL LOAD AMP TABLE HP 0.25 0.25 0.33 0.33 0.5 0.5 Form RZ-C-UH (Version H) Page 36 Type Open TEFC Open TEFC Open TEFC FLA RPM V PH FLA RPM V PH FLA RPM V PH 5.1 1750 120 1 HP 11 1750 120 1 16.4 1750 120 1 2.1 1750 208 1 6.3 1750 208 1 9.5 1750 208 1 2.3 1750 230 1 5.5 1750 240 1 8.2 1750 230 1 1.1 1750 208 3 2.9 1750 208 3 4.3 1750 208 3 1.4 1750 230 3 2.6 1750 240 3 4.
Installation Procedures Page Number _______ of ______ WARNING: Gas-fired appliances are not designed for use in hazardous atmospheres containing flammable vapors or combustible dust, or atmospheres containing chlorinated or halogenated hydrocarbons. Installations in public garages or airplane hangars are permitted when in accordance with ANSI Z223.1 and NFPA 54 codes or CAN1-B149 and enforcing authorities. FOR YOUR SAFETY What to do if you smell gas: ●● Do not try to light any appliance.
The Indoor Air Economizer Feature on Model LDAP provides “free” heat. Here’s how it works... Page Number _______ of ______ Step 3: Thermostat setting is reached, shutting off heater. Heated air naturally rises. Step 1: Wall mounted thermostat calls for heat. Step 2: Down discharge Model LDAP directs heating to the floor. As George Reznor used to say, “Because we live on the floor, not on the ceiling.
Page Number _______ of ______ Options and Accessories Apply to Unit Heater Models as Listed Stepdown Transformers - (Models F and B) Model 25 50 75 F (heater only) .25 .25 .25 F with Field-installed Optional Venter .25 .50 .50 B (heater only) .50 .50 1.0 B with Field-installed Optional Venter .50 .50 1.0 Unit Size 100 125-200 .50 .50 .50 .75 1.0 1.0 250 .50 .50 300 .50 .75 400 1.00 1.
Options and Accessories (cont'd) Page Number _______ of ______ Apply to Unit Heater Models as Listed Optional Polytube Outlet Adapter - Apply to Model B Description The optional outlet nozzle is designed to allow the attachment of polytube-type air distribution for use in greenhouse and industrial buildings. Outlet on suspended heater may be either above, below, or directly in line with the heater discharge.
Page Number _______ of ______ Optional Downturn Nozzles - Apply to Models UDAP, UDAS, UDBP, UDBS, UEAS, F and B Optional Downturn Nozzle with 25°-65° Range of Air Deflection • Optional Downturn Nozzle with 50°-90° Range of Air Deflection , IMPORTANT: On fan Models UDAP, UDAS, UEAS and F, do not use optional vertical louvers in combination with a nozzle with 50-90° range of air deflection.
Model LDAP Discharge Air Options LOUVERS Page Number _______ of ______ Airflow direction depends on how the louvers are installed INSTALLING LOUVERS After the unit is suspended/mounted, install the air directional louvers or optional nozzle.
Page Number _______ of ______ Reznor Separated Combustion Systems Following is an overall description of Separated Combustion Systems as it relates to Models UDAS and UDBS. For more specific separated combustion venting information, especially as it relates to Model UEAS, please see the appropriate installation manual. The manufacturer of Reznor heating equipment, for years, has pioneered in separated combustion system technology, eliminating “open flame” combustion problems.
Reznor RezPro® Toolbox Software UNIT HEATER SELECTION HELP Reznor now offers unit heaters with three different levels of efficiency. How can you tell which one is right for your climate and your pocketbook? Now you can compare different Reznor Unit Heaters and get specific energy savings and return on investment results for your specific area. Here’s how it works: When you open RezPro Toolbox, select the Heat Load button as indicated by the arrow in the illustration to the right.
Reznor Toolbox Software (cont'd) ENERGY ANALYZER Page Number _______ of ______ To determine the energy consumption of various unit heaters, select the Energy Analyzer button on the Toolbox screen as indicated by the arrow (right). The Energy Analyzer screen (bottom right) opens. Select the appropriate data as shown: 1. City: For this example we have selected Memphis, Tennessee. The Elevation is automatically assigned. You’ll also need to select the Design Load. (BTU Required based on the heat loss) 2.
Sample Specifications Page Number _______ of ______ Model UEAS GAS-FIRED, SEPARATED COMBUSTION UNIT HEATERS Fuel Heat Exchanger Burner Controls Combustion Air and Venting Provide (90%+) high-efficiency, separated-combustion, power vented, condensing, gas-fired unit heaters manufactured as Reznor® brand units. The unit shall be designed for use in a building with negative pressures up to 0.15 “ w.c.
Sample Specifications Page Number _______ of ______ Model UDAS GAS-FIRED, SEPARATED COMBUSTION UNIT HEATERS Fuel Heat Exchanger Burner Controls Combustion Air and Venting Provide (82%, 83%) high-efficiency, separated-combustion, power vented, gas-fired unit heaters manufactured as Reznor® brand units. The unit shall be designed for use in a building with negative pressures up to 0.15 “ w.c.
Sample Specifications Page Number _______ of ______ Model UDAS (cont'd) Certifications Unit(s) shall be design certified by the Canadian Standards Association to ANSI Z83.8b and CSA 2.6b for commercial/industrial installation. (Model sizes 30, 45, 60, 75, 100 and 125 MBH shall be certified to CSA International Requirement 10-96 - U.S., CR96-0005 - Canada for use in attached residential garage. Manufacturer must have a minimum of 50 years experience in the manufacture of gas fired unit heaters.
Sample Specifications Page Number _______ of ______ Model UDBS (cont'd) Cabinet The cabinet shall be low profile with a pre-coat or powdercoat RAL 1001 white paint finish. Finish shall be a minimum 80 gloss on G30 galvanized steel. The heat exchanger/control compartment cabinet shall be constructed so that screws are not visible from the bottom, front, or sides, except for service panel and accessories. Cabinet shall have a beveled front corner on the control side for additional cabinet rigidity.
Sample Specifications Page Number _______ of ______ Model UDAP (cont'd) Electrical Cabinet Operation shall be controlled by an integrated circuit board that includes LED diagnostic indicator lights. Supply voltage connections are made at the circuit board. 24-volt control connections shall be made on an externally mounted terminal strip with connections (W1, W2, R, and G).
Sample Specifications Combustion Air and Venting Page Number _______ of ______ Model UDBP (cont'd) The unit shall have a factory-installed power venter device to draw combustion air through an inlet in the rear of the cabinet. The combustion air/venting system shall include a vibration isolated power venter motor and wheel assembly and a combustion air pressure switch. Electrical Blower Cabinet (An approved vent cap shall be available.
Sample Specifications Page Number _______ of ______ Model B GAS-FIRED, POWER VENTED UNIT HEATERS Provide gravity-vented, high-efficiency, gas-fired unit heaters manufactured as Reznor® brand units. Units are designed to take combustion air from the indoor space and vent to the outdoors. Fuel Each Model B series unit shall be equipped for use with (natural) (propane) gas and (120/1) (230/1) (460/3) (575/3) volt power supply.
REZNOR® PRODUCT LIMITED WARRANTY Thomas & Betts Corporation warrants to the original owner-user that this Reznor product will be free from defects in material or workmanship. This warranty is limited to twelve (12) months from the date of original installation, whether or not actual use begins on that date, or eighteen (18) months from date of shipment by Thomas & Betts Corporation, whichever occurs first.
Reznor® is your global source for heating, ventilating and air conditioning equipment. For more information on Reznor HVAC Equipment, go to www.RezSpec.com or contact your local Reznor Representative by calling 800-695-1901. ©2012 Thomas & Betts Corporation, All rights reserved. Reznor® is registered in the United States and other countries. 0812 POD OG Form C-UH Printed in the U.S.A. (Version H.