Options and Accessories

TheIndoorAirEconomizerFeature
onModelLDAPprovides“free”heat.
Here’s how it works...
Step 1: Wall mounted
thermostat calls for heat.
Step 2: Down discharge Model
LDAP directs heating to the
oor. As George Reznor used
to say, “Because we live on the
oor, not on the ceiling.”
Step 3: Thermostat setting is
reached, shutting off heater.
Heated air naturally rises.
Step 4: Instead of heat remain-
ing at the ceiling or escaping
through the roof, a monitor
(separate from the wall mounted
thermostat) on Model LDAP
senses the buildup of heat at
the ceiling. This monitor triggers
the fans at a slower speed to
destratify the air and send “free”
heat back to the oor.
Another benet of Model LDAP: Using the fan(s) in the summer can improve
working conditions by alleviating stagnant air conditions and creating a cooling
effect for the occupants.
Field-Supplied
Mounting Angles
(MUST be on all
four sides of the
heater.)
Wall
Suspending the Heater
Ceiling Suspension
WARNINGS:Checkthesupportingstructuretobeusedtoverifythat
ithassufcientloadcarryingcapacitytosupporttheweightofthe
heater.Suspend theheateronlyfromthethreadednutretainersor
withamanufacturerprovidedkit.DoNOTsuspendfromtheheater
cabinet.
See dimensional drawings for hanger locations, and install the ½”-13 spring
nuts in the strut that is attached to the top of the unit. Comply with the require-
ments shown below when using threaded rod. If ordered with swivel connectors
for 1” pipe, Option CK10, attach the swivels to the spring nuts according to
illustration shown below and suspend with 1” pipe.
Locate the hardware kit shipped with the heater. The kit contains spring nuts,
hex nuts, “U”-shape ttings, and lock washers for suspending the heater. It also
includes louvers and the compression springs needed to install them.
When the heater is lifted for suspension, support the bottom of the heater with
the crate bottom. If the bottom is not supported, damage could occur. After
hanging or mounting, verify that any screws used for holding shipping brackets
were reinstalled in the cabinet.
WARNING:Allheatersmustbelevelforproperoperation.Donotplace
or add additional weight to the suspended heater.
Wall Mounting
Guidelines for Wall Mounting Model LDAP Heaters
Mounting is the responsibility of the installer. Verify that the supporting struc-
ture has sufcient load-carrying capacity to support the weight.
Prior to installation, be sure that the method of support is in agreement with
all local building codes. Check for service platform requirements.
Maintain a minimum of 2” (51mm) clearance from the discharge air open-
ings to structural supports. Additional clearance will be required if an optional
nozzle is to be eld installed.
Determining the need for installing vibration or noise isolation is the respon-
sibility of the installer.
To prevent potential movement, eld-supplied angles must be placed around
the perimeter of the heater to anchor it to the structural supports.
Structural supports must be placed as shown to prevent damage to the
heater.
All structural supports must be noncombustible materials.
Wall mounting - All structural supports and
angles are eld supplied.
Form RZ-C-UH (Version H) Page 38
Page Number _______ of ______