UDZ Venting Instructions
Table Of Contents
- VENTING INSTRUCTIONS FOR UNIT HEATERS (MODEL UBZ: SEPARATED-COMBUSTION BLOWER TYPE AND MODEL UDZ: SEPARATED-COMBUSTION FAN TYPE)
- GENERAL INFORMATION
- INSTALLATION
- APPENDIX: INSTRUCTIONS FOR ATTACHING DOUBLE-WALL TYPE B VENT PIPE TO SINGLE-WALL PIPE
- FIGURES
- Figure 1. Typical Combustion Air Inlet and Venter Outlet Connections
- Figure 2. Concentric Adapter Box
- Figure 3. Concentric Adapter Box Dimensions (Refer to Table 4)
- Figure 4. Concentric Adapter Box Connections (Refer to Table 4)
- Figure 5. Vent Terminal Options
- Figure 6. Option CC2 Components
- Figure 7. Option CC2 Installation
- Figure 8. Concentric Adapter Box Brackets
- Figure 9. Combustion Air Pipe Installation
- Figure 10. Combustion Air Pipe Through Roof
- Figure 11. Combustion Air Inlet and Vent Terminal
- Figure 12. Option CC6 Components
- Figure 13. Option CC6 Installation
- TABLES
- Table 1. Combustion Air Inlet and Venter Outlet Connection Sizes
- Table 2. Concentric (Outdoor) Pipe Sizes
- Table 3. Diameter and Length of Pipe from Heater to Concentric Adapter Box
- Table 4. Vent Pipe Opening Diameter
- Table 5. Concentric Adapter Box Vent Pipe Sizes
- Table 6. Vertical Vent Terminal/Combustion Air Package (Option CC2) Components
- Table 7. Minimum Spacing Between Center Lines of Vertical Vent Pipes
- Table 8. Horizontal Vent Terminal/Combustion Air Package (Option CC6) Components
- Table 9. Minimum Clearance Requirements for Horizontal Vent Termination Location
Revision: CP-UBZ-UDZ-VENT (02-21) 1034632-0
VENTING INSTRUCTIONS FOR UNIT HEATERS
Supersedes: — (Original Version)
GENERAL INFORMATION
This manual applies only to venting instructions and must be used with the installation manual. Both manuals are
shipped with the heater. If either manual is missing, contact your distributor before beginning installation.
Important Safety Information
Please read all information in this manual thoroughly and become familiar with the capabilities and use of your
appliance before attempting to operate or maintain this unit. Pay attention to all dangers, warnings, cautions, and
notes highlighted in this manual. Safety markings should not be ignored and are used frequently throughout to
designate a degree or level of seriousness.
DANGER: A danger statement describes a potentially hazardous situation that if not avoided, will result in severe
personal injury or death and/or property damage.
WARNING: A warning statement describes a potentially hazardous situation that if not avoided, can result in severe
personal injury and/or property damage.
CAUTION: A caution statement describes a potentially hazardous situation that if not avoided, can result in minor
or moderate personal injury and/or property damage.
NOTE: A note provides important information that should not be ignored.
⚠ CAUTION ⚠
These units should not be used in an application where the heated space temperature is below
50°F (10°C). Operating under low ambient conditions may cause condensate to form in the heat
exchanger.
⚠ DANGER ⚠
• Do not use an existing venting system. This heater requires installation of the combustion air/
vent system ordered with the unit, either option CC6 for a horizontal system or option CC2 for a
vertical system. Failure to comply could result in severe personal injury, death, and/or property
damage.
• Heaters certified for residential use are intended for the heating of non-living spaces that are
attached to or part of a structure that contains space for family living quarters. They are not
intended to be the primary source of heat in residential applications or to be used in sleeping
quarters.
• Installation should be performed by a qualified agency in accordance with these instructions.
The qualified service agency installing this unit is responsible for the installation.
Venting and Combustion Air Requirements
⚠ WARNING ⚠
All separated-combustion units MUST BE equipped with both combustion air and exhaust piping
to the outdoors.
MODEL UBZ: SEPARATED-COMBUSTION BLOWER TYPE
MODEL UDZ: SEPARATED-COMBUSTION FAN TYPE