Operating instructions
1104UESAGBEN, page 25/31
Repeat ‘Burner removal’ steps above in the opposite order.
Figure 20
Reinstall the burner
11.2.3 Burner jet
The burner jet normally needs to be replaced only when a change in gas is made.
When ordering a replacement orifi ce, provide (MJ/m3) heating value and specifi c
gravity of gas, as well as the model and serial number of the unit. When remov-
ing or replacing the burner jet be careful not to damage the venturi tube and/or the
bracket.
Ignitor - Refer to fi gure 16a and locate the ignitor. Disconnect the wire; remove the
screw and the ignitor. Clean the ignitor assembly with an emery cloth.
Spark gap must be maintained to 3 mm.
Important : When reassembling, the wire must remain attached to the ignitor.
Inspect the internal portion of the heat
exchanger (with burner assembly re-
moved).
At the burner fl ame entrance of each
tube, shine a bright light into each heat
exchanger section. With the light shin-
ing into the heat exchanger, observe the
outside surface of the tube where dis-
coloration is evident. Repeat this pro-
cedure with each heat exchanger tube.
If any light is observed in these high
temperature regions, replace the heat
exchanger.
11.2.4 Ignition system
Figure 21
Ignitor showing required
spark gap measurement
Figure 22
Flame sensor
CAUTION
Due to high voltage on
the spark wire and elec-
trode, do not touch when
energized.
Flame sensor : Refer to fi gure 16a and locate the fl ame sensor. Disconnect the
wire, remove the screw and the fl ame sensor. Clean with an emery cloth.