User's Manual

© Copyright 2003-2005 RF Code, Inc. All rights reserved. UM-C2020-R05-20030422.
No copying of this material is allowed without prior written permission. Page 14 of 28.
14
USER MANUAL – Mantis™ II Reader
Reader Settings
(R)eader # R
R - Select a new Reader to program.
Reads and displays a Reader’s saved calibration and settings from its
configuration file (SSI_info\AXnnnnnn.txt where AXnnnnnn is the
serial number). Any undefined settings will remain blank.
Errors are displayed if the info file is missing or contains bad
calibration data.
The Reader # is the s/n (serial number) on the silver label on the
underside of the Reader. When entering this number, ignore the
space between the two sets of 4 numbers and input it as a single 8-
digit alpha-numeric serial number.
Note – The utility checks for reader compatibility, and does not allow
specific readers to be uploaded with conflicting code.
(U)B processor FW U
U – Choose firmware revision for the network processor.
Prints list of available files.
Type the desired filename (case-sensitive).
An error message is displayed if the firmware file cannot be found.
(D)A processor SW D
D – Choose firmware revision for the DSP processor.
Prints list of available files.
Type the desired filename (case-sensitive).
An error message is displayed if the firmware file cannot be found.
Calibration (loaded from reader in upload process)
Display Reader calibration data.
Displays only the calibration data for the Reader at the time of the
upload process, when the data is retrieved from the Reader. This field
is informational only and cannot be modified.
Note - The calibration string is read strictly from the Reader and sent
back during the upload process; the calibration string in the file
cannot be uploaded to the Reader. This prohibits users from
modifying the calibration string in this file and de-calibrating the
Reader during the upload process.