User's Manual

© Copyright 2003 RF Code, Inc. All rights reserved. UM-C2020-R02-20030422.
No copying of this material is allowed without prior written permission. Page 10 of 27.
USER MANUAL – Mantis™ II 433.92MHz Reader
10
Environmental Limits
The Mantis™ II 433.92MHz Reader is approved for use within the
temperature ranges set forth below.
Operation: -20 to +70 degrees Celsius.
Storage: -40 to +80 degrees Celsius.
Tag Positioning
Figure 2.4 – Mantis™ 433.92MHz Tag.
Wherever possible, Mantis™ 433.92MHz Tags should be placed in the same
orientation (plane) in order to optimize the Reader’s ability to receive
transmissions from the Tag. The Tags should not be placed closer than ½
inch in proximity to one another.