User's Manual

© Copyright 2003 RF Code, Inc. All rights reserved. UM-C2020-R02-20030422.
No copying of this material is allowed without prior written permission. Page 15 of 27.
USER MANUAL – Mantis™ II 433.92MHz Reader
15
(A)RP Table display A
A – Displays the ARP Table.
When two or more Readers initially share the same IP address, it is
likely that the ARP will need to be either modified or flushed before
sequential accesses to the same IP address can be performed (due to
physical addressing). This feature provides a method of querying the
ARP table to assess IP resolution issues.
Advanced Network Settings
(1) Keep Alive Probes (default is 10) 1
1 – Change the number of keep-alive probes.
Defines the maximum number of keep-alive probes to send.
An error message will be displayed if an invalid number is entered
(and the field will be cleared).
(2) Keep Alive Signal Interval (default is 1000 ms) 2
2 – Change the keep-alive signal interval.
Defines how often keep-alive probes are sent on a connection (in
milliseconds).
An error message will be displayed if an invalid number is entered
(and the field will be cleared).
(3) Packet Size (default is 1400 bytes) 3
3 – Change the packet size.
Defines the maximum packet size in bytes.
An error message will be displayed if an invalid number is entered
(and the field will be cleared).
(4) Packet Timeout (default is 500 ms) 4
4 – Change packet timeout setting.
Defines the packet timeout (in milliseconds).
An error message will be displayed if an invalid number is entered
(and the field will be cleared).