User's Manual

© Copyright 2003 RF Code, Inc. All rights reserved. UM-C2020-R02-20030422.
No copying of this material is allowed without prior written permission. Page 18 of 27.
USER MANUAL – Mantis™ II 433.92MHz Reader
18
Serial Settings
The Mantis™ II 433.92MHz Reader supports operation via a standard RS-
232 serial port, which may be used instead of, or in conjunction with the
Ethernet jack. The Reader will accept commands from either source, or
output results to both. In addition, the serial port doubles as a diagnostic
port, providing valuable feedback about Reader functionality and
configuration during power-up and programming.
Having selected the appropriate serial port (COM port) on your system, use
the following settings in your communications package:
Bits Per Second: 115200
Data Bits: 8
Parity: None
Stop bits: 1
Flow Control: None
ASCII Setup
ASCII Sending
Send line ends with line feeds: NO
Echo typed characters locally: NO
Line delay: 10 ms
Character delay: 0
ASCII Receiving
Append line feeds to incoming line ends: YES
Force incoming data to 7-bit ASCII: NO
Wrap lines: NO