User's Manual

Active RFID Tags: Features, Specifications, and Deployment Guidelines
42
Mounting Instructions for Standard Form Factor Asset Tags
The following mounting instructions apply to M100, M102-I, M131, M171, and M172-i asset tags:
1. Ensure that the surface of the asset is clean and dry.
2. Remove the liner backing of the adhesive and apply firmly to the surface of the asset. The tag adhesive bonds
when force is applied, rather than by air activation.
3. Press the tag down on the surface of the asset with 15 pounds of force for three (3) seconds or longer.
NOTE: The ideal temperature range when applying these tags with adhesive is 60°F (21°C) to 100°F (38°C). Do
not try to mount these tags with adhesive if the surface temperature is below 50°F (10°C) because the
adhesive becomes too firm to adhere readily to the asset surface.