2.2.5. Connecting Digital Inputs/Outputs
The INfinity 610 is equipped with a general purpose digital input/output
(I/O) port that provides four optically isolated 5-24 VDC input signals and
four open-collector output signals. The digital inputs can be used as general
purpose inputs or to trigger the reader for tag reading. These inputs can be
configured to provide an external read trigger from proximity sensors, photo
switches, or other devices.
The digital outputs can be used as general purpose outputs, to indicate tag
reading activity, or to indicate the reader is transmitting (RF On). The
outputs can also be configured to trigger conveyor gates or other access
control and sorting devices. For detailed information on configuring the
digital inputs and outputs refer to Chapter 7.
2.2.6. Connecting the Power
Connect the 24 VDC power adapter to the reader and connect the power
supply to your 100–240 VAC, 50-60 Hz power source. Allow 30 seconds for
the reader to initialize.