Profile feature Value (lead free)
Ramp up rate
3
o
C /s
Pre-heat Temperature
- Temperature Min (T
Smin
)
- Temperature Max (T
smax
)
- Pre-heat time
150
0
C
200
0
C
60-100s
Peak Temperature (T
P
)
240
0
C
Time at T
P
10-20sec
Ramp down rate
6
0
C/s
Time from 25
0
C to peak
8 mins max.
Module Re-flow Guide
LAMBDA62 is a 4 layer PCB, re-flow is based on IPC/JEDEC JSTD020C July 2004
Additional FCC requirements when using the P9OLAMBDA62
Provided the installation requirements are followed, further radio performance testing is not required
when using this FCC modular approved product. The complete product that the module is used in re-
quires the wording on the finished product label to include “Contains FCC Module ID: P9OLAMBDA62”.
Unintentional radiated spurious emissions must be performed on the finished product in accordance with
FCC Part 15.109 requirements, the limits as for a Class B product. The antenna cable assembly CBA-
UFLSMARP-10 must be used to provide a non-standard reverse SMA bulkhead connector. It is recom-
mended that the FLEXI-SMA-918 (reverse SMA connector) antenna is used, which is available from RF
Solutions. The antenna must not have a maximum gain greater than 2dBi. Colocation of transmitters is
not recommended without further radio testing to ensure the maximum declared EMF is not exceeded. It
is recommended not to operate the transceiver with persons closer than 20cm to the antenna.
Refer to FCC KDB996369 D04, Module Integration Guide for additional information.