RF Technology PA501    Page 21 
B PA501 FACTORY ALIGNMENT AND TEST  B3 Checking Mismatched Loads  
B3  Checking Mismatched Loads 
The correct operation of the calibrated mismatch loads may be checked using the 
equipment available for other tests. Place the Directional Power Meter between the 
driving amplifier and the load to be tested. Adjust the generator to 500MHz, output on. 
Measure the forward and reverse powers. The return loss is calculated at  
RL = 10 log (PR/PF). 