Operating instructions
Page 1 RF Technology R50
1  OPERATING INSTRUCTIONS
1 Operating Instructions
1.1 Front  Panel Controls and Indicators
1.1.1 Monitor Volume
The Mon. Volume control is used to adjust the volume of the internal loudspeaker and
any external speaker connected to the test socket. It does not effect the level of
the 600 Ohm line output level, nor the direct audio output level.
1.1.2 Monitor Squelch
The MON. SQ. switch allows the normal  squelch  functions controlling the monitor
output to be disabled. When the switch is in the MON. SQ. position the audio
at the monitor speaker is controlled by the noise detector. The CTCSS, carrier,
tone, DCS, and external squelch functions will not stop the audio from being
broadcast by the speaker.  This can be useful when you are trying to trace the
source of on channel interference or when setting the noise squelch threshold.
The audio from the 
600 Ohm line output, and the direct audio output, is  not
effected by the switch position.
1.1.3 N.SQ
The  N.SQ  trimpot  is  used  to  set  the  noise  squelch  sensitivity.  Use  the  following
procedure to set the noise squelch to maximum sensitivity.
 (a)  Set the  toggle  switch  to  the  MON.SQ.  position  and  set  the  MON  VOLUME
control to 9 o'clock.
 (b) Turn the N.SQ. 
adjustment counter clockwise until the squelch opens and noise is
heard from the speaker. Adjust the VOLUME to a comfortable listening level.
 (c) In the absence of any on channel signal, 
Turn the N.SQ. 
screw clockwise until the
until the noise in the speaker is muted.
WARNING
Changes  or  modifications not  expressly  approved  by  RF
Technology  could void your  authority  to  operate
this equipment. Specifications may vary from those
given  in  this  document  in  accordance  with
requirements of  local  authorities.    RF  Technology
equipment is subject to continual improvement and
RF  Technology  reserves  the  right  to  change
performance  and  specification  without  further
notice.