Technical data

Manual – Gear Units and Gearmotors 
99
7
Overhung loads (→ GM, → MM)
Project Planning for AC Motors
7.8 Overhung loads (→ GM, → MM)
Refer to the section "Project Planning for Gear Units"Overhung loads and axial forces/
for general information about overhung loads. The following table lists the permitted
overhung loads (top value) and axial forces (bottom value) of AC motors:
Overhung load 
conversion for 
off-center force 
application
The permitted overhung loads must be calculated using the following formulae in the
event that force is not applied at the center of the shaft end. The smaller of the two
values F
xL
 (according to bearing service life) and F
xW
 (according to shaft strength) is the
permitted value for the overhung load at point x. Note that the calculations apply to M
N
.
F
xL
 based on 
bearing life
F
xW
 from the shaft 
strength
Mount-
ing 
position
[rpm]
No. of 
poles
Permitted overhung load F
R
 [lb]
Permitted axial load F
A
 [lb]; F
A_tension
 = F
A_pressure
Size
63 71 80 90 100 112 132S
132ML 
132M
160M 160L 180 200 225
250
280
Foot 
mounted 
motor
900
8
-
-
156 
45
205 
54
790 
72
380 
90
395 
108
425 
126
585 
144
810 
215
850 
215
1260 
1290
1350 
450
-
-
-
-
1200
6
-
-
144 
36
189 
45
270 
54
340 
72
360 
90
395 
108
540 
126
740 
180
765 
180
1120 
250
1240 
425
-
-
1800
560
1800
4
-
-
126 
27
162 
36
235 
47
290 
61
315 
61
335 
61
450
90
585 
144
695 
144
1010 
210
1060 
540
1570 
540
1800 
560
3600
2
-
-
90 
18
117 
22
162 
33
215 
43
220 
45
245 
47
325 
72
450 
108
515 
108
775 
180
830 
415
-
-
-
-
Flange-
mounted 
motor
900
8
-
-
191 
56
260 
67
3600 
90
470 
112
495 
135
540 
157
7220 
180
1030 
270
1080 
270
1570 
360
1690 
560
-
-
-
-
1200
6
135 
34
180 
45
235 
56
335 
67
425 
90
450 
112
495 
135
650 
157
920 
225
970 
2250
1420 
315
1530 
540
-
-
2470
675
1800
4
112 
25
157 
31
200 
45
290 
56
370 
79
395 
79
425 
79
560 
112
720 
180
880 
180
1260 
270
1330 
675
1960 
675
2020 
585
3600
2
90 
16
112 
22
146 
29
200 
40
270 
54
270 
56
290 
58
405 
90
560 
135
650 
135
970 
225
1030 
515
-
-
-
-
F= F
xL R
•
a
b + x
[lb]
F
R
= Permitted overhung load (x = l/2) [lb]
x = Distance from the shaft shoulder to the force application point [in]
a, b, f = Motor constant for overhung load conversion [in]
c = Motor constant for overhung load conversion [in]
F=
xW
c • 10
3
f + x
[lb]