User's Manual

41
USER MANUAL - TRANSMITTER DS SERIES - 30 - 50 - 100 - 500 - 1000W
Rev 1.3
Firmware Reset Procedure
1. Confi gure the PC on the same class of IP addresses of the Transmi er (for
example 192.168.178.1)
2. Connect it with a cable to the LAN connector on the rear panel (fi gure C1) of the
TX/Amplifi er.
3. Launch the TFTP Client So ware.
4. Confi gure the Client as in Figure C2:
- TFTP server: 192.168.178.55
- Opera on: Upload
- Format: Binary
- Local File Name: click on the folder bu on and select the fi le, for example
Reset- T500A0717044.bin”
- Remote File Name: rmware.bin (Be carefully!!! Other fi le name doesn’t
work)
5. Make sure the TX is disconnected from AC line or the rear power switch is in off
posi on.
6. Push the HOME bu on and turn on the TX; when the leds start blinking leave
the bu on. The leds con nue to blink and the LCD display is back.
Fig. C2: TFTP Client So ware screen