USER MANUAL - TRANSMITTER DS SERIES - 30 - 50 - 100 - 500 - 1000W
Rev 1.3
Appendix D - Log event & Alarms list
The system is equipped with a register of alarms, consulted both on the display
that from web interfaces (where available). Each event that generates an alarm is
registered with date and me at which the event occurred. In the following tables are
detailed individual alarm signals.
Text Alarms Descrip on
TX Power UP Switching on the device
TX Powe DOWN Turn off the device
TX in Local Mode TX is opera onal only in local mode
TX in Remote Mode TX is opera onal only in Remote mode
TX ON TX in power
TX Stand-By TX in stand-by
Alarm - OverCurrent Absorbed current higher than that allowed
Reset - OverCurrent Reset following to the Alarm - Over Current
Reset - FAULT It was carried out a reset of all alarms blockers
Alarm - PowerGood Power below the threshold of control set
Alarm - AudioGood No sound for a me higher than the set value
Alarm - AC Line OFF No mains powered device in POE
AC Line ON Electrical network ok
Alarm - RF Burning Alarm RF Sec on likely outbreak transistor
Alarm - 485TX Fault Connec on 485 absent
Alarm - Pmax Power grater than nominal
Reset - Pmax Alarm Reset following Power greater than nominal
Alarm - Temperature RF temperature greater than 80°
Reset - Temperature Reset followinf RF temperature greater than 80°
Alarm - VSWR So . Prot. Alarm for increase Refl ected Power Block So ware
Reset - ACK VSWR HW Reset following to the Alarm VSWR HW
Alarm - VSWR HW Prot. Alarm for increase Refl ected Power Block Hardware
Playing ID-Code Ac va on ID-Code and airing
Alarm - Fan Fault Alarm Fans blocked
Alarm - Modules Fault Alarm RF Pallets Error
Alarm - Dera ng Pwr Alarm power reduc on due to Alarm VSWR
Power Reduc on Prog Power Reduc on ac va on
Local Access Denied If enabled password access denied locally
Web Accesss Denied Access denied on the web
AES/EBU Error Error of AES/EBU
Password Modifi ed Password Changed