User's Manual Part 2

DSPbR Series User’s Manual
Document Number 00000.B Page 28/75
down menu will indicate a level of up to +46dBm the level remains constant at +43dBm as the maximum. Refer
to Table 3.
GUI Channel Configuration Overview page
When an 8-Ch combiner filter unit has been fitted in either the uplink or downlink or both, the provided tick box
needs to be activated “per channel” feeding through the 8-Ch combiner filter unit in order for the maximum
output power to be auto-adjusted. This will effectively reduce the maximum output power setting of the RFBE to
+ 40dBm from +46dBm which will cater for up to 6 combined channels.
Should the user wish to manually adjust the maximum output power level, Table 3 will indicates the MAXIMUM
output power level setting permissible without causing damage to the 8-Ch Combiner Filter Unit.
RFBE Max Output power
setting via GUI 805-870MHz
Freq Range
Approx Output Power at output of
8Ch combiner filter unit
Filter tick box activated
Number of
carriers
RFBE Max Output
power setting via GUI
400-490MHz Freq
Range
Indicated Actual 400-490MHz 806-870MHz
2 46dBm 46dBm 43dBm 34.5dBm 31.5dBm
3 46dBm 46dBm 43dBm 34.5dBm 31.5dBm
4 44dBm 43dBm 43dBm 32.5dBm 31.5dBm
5 42dBm 42dBm 42dBm 30.5dBm 30.5dBm
6 40dBm 40dBm 40dBm 28.5dBm 28.5dBm
7 39dBm 39dBm 39dBm 27.5dBm 27.5dBm
8 38dBm 38dBm 38dBm 26.5dBm 26.5dBm
Table 3 8-Ch Internal Combiner Filter, per Carrier Max Power Settings
8-Ch Combiner Filter “Tick