User`s manual
PA5
16 Series User’s Manual
Asia Pacific | EMEA | Americas 15
HE
LP
Pu
rpose: Displays a brief summary of the available commands.
Syntax: help
The system responds by displaying help screens.
RESET REVPWR
Pu
rpose: Resets the Reverse Power shutdown.
Syntax: reset revpwr
Example: Type: RESET REVPWR
Response: >
SET BAUD
Pu
rpose: Sets the serial interface baud rate.
Syntax: set baud {1200 | 2400 | 4800 | 9600 | 19200}
Example: Type: SET BAUD 19200
Response: The new serial baud rate will be activated now.
Press any key to continue
Comment After a key is pressed, the new data rate will be active, so the terminal data rate should be
changed either immediately prior to pressing the key, or immediately after.
The default data rate out of the factory is 9600 baud.
WARNING: If the baud rate is changed from the factory default, you may want to record this on the repeater
enclosure for other maintenance staff.
SET GAIN
Pu
rpose: Used to set the amplifier gain.
Syntax: set gain {50…62}
Example: Type: SET GAIN 56
Response: > Gain = 56dB