User`s manual

PA5
16 Series User’s Manual
Asia Pacific | EMEA | Americas 16
SET
LEVEL
Pu
rpose: Used to set the reference output power level.
Syntax: set level
Example: Type: SET LEVEL
Response: Current output power = 41.3dBm.
This level will become the nominal level for alarm purposes.
Are you sure? (YES/NO) >
Type: YES
Comment If the output power level deviates by more than +/-6dB from the level set with this command, a
Major alarm condition will be activated.
If the reference output power level has not yet been configured, no output power level alarms will
be generated.
SET LVLDELAY
Pu
rpose: Sets the delay period before a level alarm is raised.
Syntax: set lvldelay {1..99}
Example: Type: SET LVLDELAY 15
Response: Delay to Level Alarm = 15 Sec
Comment The output power level needs to be more than 6dB above or below the Reference level for this period
of time before an alarm is signalled.
SET NAME
Pu
rpose: Used to designate the name of the site.
Syntax: set name {name}
Example: Type: SET NAME SITE-1234A
Response: >
Comment The name can be up to 16 characters long. Any of the visible characters from a PC keyboard may
be used, except for a space. When other commands such as SHOW ID and SHOW STATUS are
used, they will include the site name.