Specification Sheet
Air
Performance Data
16AJL Series
11
Outdoor
Unit
16AJL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
36
RCFL-H*3824
ROCA-070E03
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 16 12.5
800 [378] 0
2 23700 [6.9] 11100 [3.3] 1000 [472] 77
ROCA-070E04
1 19300 [5.7] 9100 [2.7]
34800 [10.2] 16 12.5
800 [378] 0
2 23700 [6.9] 11100 [3.3] 1000 [472] 77
ROLA-070E03
1 20100 [5.9] 8900 [2.6]
35800 [10.5] 15.5 12.5
900 [425] 0
2 25400 [7.4] 10400 [3.0] 1175 [554] 77
ROLA-070E04
1 20100 [5.9] 8900 [2.6]
35800 [10.5] 15.5 12.5
900 [425] 0
2 25400 [7.4] 10400 [3.0] 1175 [554] 77
ROLA-115E05
1 20100 [5.9] 8900 [2.6]
36000 [10.5] 16 12.5
900 [425] 0
2 25700 [7.5] 10300 [3.0] 1200 [566] 77
RCFL-H*3824+RXMD-C04 Coil Only
1 18700 [5.5] 9100 [2.7]
34600 [10.1] 14 11.5
800 [378] 0
2 23700 [6.9] 10900 [3.2] 1050 [495] 77
RCFN-H*3624
RGFE-09?ZCM?
1 22200 [6.5] 8400 [2.5]
38500 [11.3] 16 13
875 [413] 0
2 29000 [8.5] 9500 [2.8] 1200 [566] 77
RGFG-09?ZCM?
1 22200 [6.5] 8400 [2.5]
38500 [11.3] 16 13
875 [413] 0
2 29000 [8.5] 9500 [2.8] 1200 [566] 77
RGFG-10?ZCM?
1 22300 [6.5] 8300 [2.4]
38500 [11.3] 16 13
900 [425] 0
2 29000 [8.5] 9500 [2.8] 1200 [566] 77
RGGE-10?ZCM?
1 22200 [6.5] 8400 [2.5]
38500 [11.3] 16 13
875 [413] 0
2 29000 [8.5] 9500 [2.8] 1200 [566] 77
RGGE-12?RCM?
1 22200 [6.5] 8400 [2.5]
38500 [11.3] 16 13
875 [413] 0
2 29000 [8.5] 9500 [2.8] 1200 [566] 77
RGJF-10?ZCM?
1 22200 [6.5] 8400 [2.5]
38500 [11.3] 16 13
875 [413] 0
2 29000 [8.5] 9500 [2.8] 1200 [566] 77
RGJF-12?RCM?
1 22200 [6.5] 8400 [2.5]
38500 [11.3] 16 13
875 [413] 0
2 29000 [8.5] 9500 [2.8] 1200 [566] 77
RGLE-10?BRM?
1 22200 [6.5] 8400 [2.5]
38500 [11.3] 16 13
875 [413] 0
2 29000 [8.5] 9500 [2.8] 1200 [566] 77
RGPE-12?ARM?
1 22200 [6.5] 8400 [2.5]
38500 [11.3] 16 13
875 [413] 0
2 29000 [8.5] 9500 [2.8] 1200 [566] 77
RGRM-07?YBG?
1 21700 [6.4] 8500 [2.5]
37800 [11.1] 15 12
850 [401] 0
2 28300 [8.3] 9500 [2.8] 1200 [566] 77
RGRM-10?ZAJ?
1 22000 [6.4] 8400 [2.5]
38000 [11.1] 16 13
875 [413] 0
2 28300 [8.3] 9700 [2.8] 1150 [543] 77
RGTM-07?RBG?
1 21400 [6.3] 8600 [2.5]
37800 [11.1] 16 13
800 [378] 0
2 27600 [8.1] 10200 [3.0] 1050 [495] 77
ROCA-070E03
1 23200 [6.8] 8000 [2.3]
38500 [11.3] 16 13
1000 [472] 0
2 29000 [8.5] 9500 [2.8] 1200 [566] 77
ROCA-070E04
1 23200 [6.8] 8000 [2.3]
38500 [11.3] 16 13
1000 [472] 0
2 29000 [8.5] 9500 [2.8] 1200 [566] 77
ROLA-070E03
1 22300 [6.5] 8300 [2.4]
38500 [11.3] 16 13
900 [425] 0
2 28900 [8.5] 9600 [2.8] 1175 [554] 77
ROLA-070E04
1 22300 [6.5] 8300 [2.4]
38500 [11.3] 16 13
900 [425] 0
2 28900 [8.5] 9600 [2.8] 1175 [554] 77
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling