Specification Sheet
Air
Performance Data
16AJL Series
17
Outdoor
Unit
16AJL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
60
RCFL-H*6024
RGRM-12?RAJ?
1 30400 [8.9] 14600 [4.3]
56000 [16.4] 15.5 11.5
1225 [578] 0
2 39200 [11.5] 16800 [4.9] 1625 [767] 77
RGTM-07?RBG?
1 31600 [9.3] 13900 [4.1]
56500 [16.6] 15 11.5
1325 [625] 0
2 40300 [11.8] 16200 [4.7] 1675 [790] 77
RGTM-09?ZAJ?
1 31200 [9.1] 14300 [4.2]
56000 [16.4] 15.5 11.5
1250 [590] 0
2 39200 [11.5] 16800 [4.9] 1600 [755] 77
RGTM-10?RBJ?
1 31300 [9.2] 14200 [4.2]
56500 [16.6] 15.5 11.5
1275 [602] 0
2 40300 [11.8] 16200 [4.7] 1675 [790] 77
ROLA-070E04
1 30400 [8.9] 14600 [4.3]
56000 [16.4] 15.5 11.5
1175 [554] 0
2 39200 [11.5] 16800 [4.9] 1600 [755] 77
ROLA-115E05
1 30400 [8.9] 14600 [4.3]
56500 [16.6] 15.5 11.5
1200 [566] 0
2 39700 [11.6] 16800 [4.9] 1600 [755] 77
RCFL-H*6024+RXMD-C04 Coil Only
1 29900 [8.8] 14600 [4.3]
56500 [16.6] 14 11.5
1200 [566] 0
2 39700 [11.6] 16800 [4.9] 1600 [755] 77
RCFN-H*6024
RGFE-09?ZCM?
1 30400 [8.9] 14600 [4.3]
56000 [16.4] 15 11
1200 [566] 0
2 39200 [11.5] 16800 [4.9] 1600 [755] 77
RGFE-10?ZCM?
1 30400 [8.9] 14600 [4.3]
56000 [16.4] 15 11
1225 [578] 0
2 39200 [11.5] 16800 [4.9] 1600 [755] 77
RGFE-12?RCM?
1 30400 [8.9] 14600 [4.3]
56000 [16.4] 15.5 11.5
1225 [578] 0
2 39200 [11.5] 16800 [4.9] 1625 [767] 77
RGFG-09?ZCM?
1 30400 [8.9] 14600 [4.3]
56000 [16.4] 15 11
1200 [566] 0
2 39200 [11.5] 16800 [4.9] 1600 [755] 77
RGFG-10?ZCM?
1 30400 [8.9] 14600 [4.3]
56500 [16.6] 15 11
1200 [566] 0
2 40100 [11.7] 16400 [4.8] 1650 [779] 77
RGFG-12?RCM?
1 30400 [8.9] 14600 [4.3]
56000 [16.4] 15.5 11.5
1225 [578] 0
2 39200 [11.5] 16800 [4.9] 1625 [767] 77
RGGE-09?ZCM?
1 30400 [8.9] 14600 [4.3]
56000 [16.4] 15.5 11.5
1225 [578] 0
2 39200 [11.5] 16800 [4.9] 1600 [755] 77
RGGE-10?ZCM?
1 30400 [8.9] 14600 [4.3]
56000 [16.4] 15.5 11.5
1200 [566] 0
2 39200 [11.5] 16800 [4.9] 1600 [755] 77
RGGE-12?RCM?
1 30400 [8.9] 14600 [4.3]
56500 [16.6] 15.5 11.5
1200 [566] 0
2 39700 [11.6] 16800 [4.9] 1575 [743] 77
RGJF-09?ZCM?
1 30400 [8.9] 14600 [4.3]
56000 [16.4] 15.5 11.5
1225 [578] 0
2 39200 [11.5] 16800 [4.9] 1600 [755] 77
RGJF-10?ZCM?
1 30400 [8.9] 14600 [4.3]
56000 [16.4] 15.5 11.5
1200 [566] 0
2 39200 [11.5] 16800 [4.9] 1600 [755] 77
RGJF-12?RCM?
1 30400 [8.9] 14600 [4.3]
56500 [16.6] 15.5 11.5
1200 [566] 0
2 39700 [11.6] 16800 [4.9] 1575 [743] 77
RGLE-07?BRQ?
1 30400 [8.9] 14600 [4.3]
56500 [16.6] 15.5 11.5
1225 [578] 0
2 39700 [11.6] 16800 [4.9] 1600 [755] 77
RGLE-10?BRM?
1 30400 [8.9] 14600 [4.3]
56500 [16.6] 16 12
1200 [566] 0
2 39700 [11.6] 16800 [4.9] 1600 [755] 77
RGLE-12?ARM?
1 30400 [8.9] 14600 [4.3]
56500 [16.6] 16 12
1225 [578] 0
2 39700 [11.6] 16800 [4.9] 1600 [755] 77
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling