Specification Sheet
Air
Performance Data
16AJL Series
6
Outdoor
Unit
16AJL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
24
RCFN-H*2421
RGGE-07?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGJF-07?MCK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGLE-07?AMK?
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGPE-05?BMK?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RGRM-04?MAE?
1 14900 [4.4] 6700 [2.0]
25800 [7.6] 16 13
575 [271] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
ROCA-070E03
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
ROLA-070E03
1 15100 [4.4] 6700 [2.0]
25800 [7.6] 16 13
600 [283] 0
2 18800 [5.5] 7000 [2.1] 800 [378] 74
RCFN-H*2421+RXMD-C04 Coil Only
1 14000 [4.1] 6800 [2.0]
24800 [7.3] 14.5 12
525 [248] 0
2 17500 [5.1] 7300 [2.1] 700 [330] 74
RCSL-H*2621 RHPL-HM2421
1 14700 [4.3] 6500 [1.9]
25000 [7.3] 16 13
600 [283] 0
2 18200 [5.3] 6800 [2.0] 800 [378] 74
RCSN-H*2421 RHPN-HM2421
1 14900 [4.4] 6700 [2.0]
26000 [7.6] 16 13
575 [271] 0
2 19000 [5.6] 7000 [2.1] 800 [378] 74
36
RCSL-H*3821
➀
RHML-HM3621
1 19500 [5.7] 9100 [2.7]
35400 [10.4] 16 13
800 [378] 0
2 24500 [7.2] 10900 [3.2] 1050 [495] 77
1 - dehumid 0 [0.0] 0 [0.0] 0 [0]
2 - dehumid 0 [0.0] 0 [0.0] 0 [0]
RCFL-H*3617
RGFE-06?MCK?
1 18400 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGFE-07?MCK?
1 18400 [5.4] 9000 [2.6]
34600 [10.1] 14.5 12
725 [342] 0
2 23800 [7.0] 10800 [3.2] 1025 [484] 77
RGFG-06?MCK?
1 18400 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGFG-07?MCK?
1 19200 [5.6] 8800 [2.6]
34200 [10.0] 14.5 12
800 [378] 0
2 23200 [6.8] 11000 [3.2] 1000 [472] 77
RGGE-06?MCK?
1 18600 [5.4] 9000 [2.6]
34800 [10.2] 14.5 12
725 [342] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGGE-07?MCK?
1 18700 [5.5] 8900 [2.6]
34800 [10.2] 14.5 12
750 [354] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGJF-06?MCK?
1 18600 [5.4] 9000 [2.6]
34800 [10.2] 14.5 12
725 [342] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGJF-07?MCK?
1 18700 [5.5] 8900 [2.6]
34800 [10.2] 14.5 12
750 [354] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGLE-07?AMK?
1 18900 [5.5] 8900 [2.6]
34800 [10.2] 15 12.5
750 [354] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGPE-05?BMK?
1 18700 [5.5] 8900 [2.6]
34400 [10.1] 14.5 12
750 [354] 0
2 23300 [6.8] 11100 [3.3] 975 [460] 77
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling