Specification Sheet
Air
Performance Data
16AJL Series
7
Outdoor
Unit
16AJL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor
Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
36
RCFL-H*3617
RGPE-07?AMK?
1 18600 [5.4] 9000 [2.6]
34400 [10.1] 15 12.5
725 [342] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGRM-04?MAE?
1 18700 [5.5] 8900 [2.6]
34600 [10.1] 14.5 12
750 [354] 0
2 23800 [7.0] 10800 [3.2] 1025 [484] 77
RGRM-06?MAE?
1 19200 [5.6] 8800 [2.6]
34400 [10.1] 14.5 12
775 [366] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGRM-07?MAE?
1 19000 [5.6] 8800 [2.6]
34400 [10.1] 14 11.5
800 [378] 0
2 23600 [6.9] 10800 [3.2] 1025 [484] 77
RGTM-06?MAE?
1 19900 [5.8] 8500 [2.5]
34600 [10.1] 14.5 12
900 [425] 0
2 23800 [7.0] 10800 [3.2] 1025 [484] 77
ROCA-070E03
1 19200 [5.6] 8800 [2.6]
34600 [10.1] 15 12.5
800 [378] 0
2 23600 [6.9] 11000 [3.2] 1000 [472] 77
ROCA-070E04
1 19200 [5.6] 8800 [2.6]
34600 [10.1] 15 12.5
800 [378] 0
2 23600 [6.9] 11000 [3.2] 1000 [472] 77
ROLA-070E03
1 18600 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23300 [6.8] 11100 [3.3] 975 [460] 77
ROLA-070E04
1 18600 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23300 [6.8] 11100 [3.3] 975 [460] 77
RCFL-H*3617+RXMD-C04 Coil Only
1 18600 [5.4] 8800 [2.6]
34400 [10.1] 13.5 11
800 [378] 0
2 23600 [6.9] 10800 [3.2] 1050 [495] 77
RCFL-H*3621
RGFE-06?MCK?
1 18600 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGFE-07?MCK?
1 18600 [5.4] 9000 [2.6]
34600 [10.1] 14.5 12
725 [342] 0
2 23800 [7.0] 10800 [3.2] 1025 [484] 77
RGFE-09?ZCM?
1 19800 [5.8] 8600 [2.5]
35400 [10.4] 14.5 12
875 [413] 0
2 25200 [7.4] 10200 [3.0] 1200 [566] 77
RGFG-06?MCK?
1 18600 [5.4] 9000 [2.6]
34400 [10.1] 14.5 12
725 [342] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGFG-07?MCK?
1 19200 [5.6] 8800 [2.6]
34400 [10.1] 14.5 12
800 [378] 0
2 23400 [6.9] 11000 [3.2] 1000 [472] 77
RGFG-09?ZCM?
1 19800 [5.8] 8600 [2.5]
35400 [10.4] 14.5 12
875 [413] 0
2 25200 [7.4] 10200 [3.0] 1200 [566] 77
RGFG-10?ZCM?
1 19900 [5.8] 8500 [2.5]
35400 [10.4] 14.5 12
900 [425] 0
2 25200 [7.4] 10200 [3.0] 1200 [566] 77
RGGE-06?MCK?
1 18600 [5.4] 9000 [2.6]
34800 [10.2] 14.5 12
725 [342] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGGE-07?MCK?
1 18700 [5.5] 8900 [2.6]
34800 [10.2] 14.5 12
750 [354] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGGE-10?ZCM?
1 19800 [5.8] 8600 [2.5]
35400 [10.4] 14.5 12
875 [413] 0
2 25200 [7.4] 10200 [3.0] 1200 [566] 77
RGJF-06?MCK?
1 18600 [5.4] 9000 [2.6]
34800 [10.2] 14.5 12
725 [342] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
RGJF-07?MCK?
1 18700 [5.5] 8900 [2.6]
34800 [10.2] 14.5 12
750 [354] 0
2 24000 [7.0] 10800 [3.2] 1025 [484] 77
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures.
[ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling