Specification Sheet
Air
Accessories
RGLE Series
9
DOWNFLOW WARNING: Unit design is certified for installation on non-
combustible floor. A special factory supplied combustible floor sub-
base is required when installing on a combustible floor. Failure to install
the sub-base may result in fire, property damage and personal injury.
FOR HIGH ALTITUDES:
HIGH ALTITUDE OPTION CODE: U.S. & Canada –
None required for high altitudes.
HIGH ALTITUDE CONVERSION KITS: U.S. & Canada –
None required for high altitudes.
80+ HIGH ALTITUDE INSTRUCTIONS
Caution: Always follow National Fuel Gas Code (NFGC) guidelines when
converting for high altitudes. High altitude option codes are not required for
these models. However, the burner orifice size needs to be recalculated
and verified at elevations above 2000 ft. See Installation Instructions for
more information.
NOTE: For Canadian installations only, an optional derate (manifold gas
pressure reduction) method may be used to adjust the furnace for
altitude. See Installation Instructions for more information. This
optional method may NOT be used for U.S. installations.
RXGW-B01 Chimney Adapter:
See Installation Instructions for application limitations.
COMBUSTIBLE FLOOR BASE DIMENSIONS
COMBUSTIBLE
FLOOR BASE
USE WITH
FURNACE SIZES
A
IN. [mm]
B
IN. [mm]
C
IN. [mm]
RXGC-B21
RGLE-07EBRQ,
RGLE-10EBRM
21
1
/2 [546] 20
1
/4 [514] 18
1
/4 [464]
RXGC-B24 RGLE-12EARMR 25
1
/4 [635] 23
3
/4 [603] 21
3
/4 [552]
RXGC-B17 RGLE-07EAMK
18
1
/4 [457] 16
3
/4 [425] 14
3
/4 [451]
SUPPLY AIR SENSOR
(For Displaying Supply Air Temp on Communicating Systems Only).
(Do not install on non-communicating configurations).
Part #47-24255-01 or equivalent.
RXPF-F01 and F02
FOSSIL FUEL KITS—are for use with Rheem Heat Pumps and
Super Quiet 80 warm air furnaces. The RXPF-F02 also meets TVA
requirements.
RXGF-CC*
FILTER RACK—Downflow top return mount.
NOTE: Filter racks are shipped without filters.
*Filters available through PROSTOCK
®
.
[ ] Designates Metric Conversions
Contractor Benefits:
• Multi-Purpose Thermostat-Setup, Control & Diagnostics
• Auto-Configuration – No Manual Settings Required in the Field
• System History – More Accurate Diagnostics
• Easy Installation – Requires only 4 wires
• Diagnostic Messages (Service Access to Fault Codes)
• Blower Adjustment in Heat and Cool
• Programmable Fan
• USB Interface for contractor contact information and thermostat
programming
Homeowner Benefits:
• Scrolling System Status
• De-Humidification Control
• Humidification Control
• Heat/Cool/Auto Change-over
• Outdoor Temperature Display
• Backlight On/Off
• Intelligent Scheduling Ramp-Up/Program Anticipation
• Audio Notifications On/Off
• Air Filter, UV Lights & Humidifier Maintenance Reminder
• Temperature Offset
• Continuous Fan (Hi, Med, Lo)
RHC-TST550CMMS
THERMOSTATS
RECOMMENDED COMMUNICATING THERMOSTAT
(For Communicating Configurations Only)