Specification Sheet
Air
Performance Data
RARL- JEC Series
14
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEC RCFL-H*3824
RGFE-12?RCM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15 12
875 [413] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGFG-09?ZCM?
1 19000 [5.6] 9600 [2.8]
35400 [10.4] 14.5 12
875 [413] 71
2 24300 [7.1] 11100 [3.3] 1200 [566] 72
RGFG-10?ZCM?
1 19600 [5.7] 9400 [2.8]
35400 [10.4] 15 12
900 [425] 71
2 24300 [7.1] 11100 [3.3] 1200 [566] 72
RGFG-12?RCM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15 12
875 [413] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGGE-09?ZCM?
1 19000 [5.6] 9600 [2.8]
35600 [10.4] 15 12
875 [413] 71
2 24600 [7.2] 11000 [3.2] 1225 [578] 72
RGGE-10?ZCM?
1 19000 [5.6] 9600 [2.8]
35400 [10.4] 14.5 12
875 [413] 71
2 24300 [7.1] 11100 [3.3] 1200 [566] 72
RGGE-12?RCM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15.1 12.5
875 [413] 71
2 24700 [7.2] 11100 [3.3] 1200 [566] 72
RGJF-09?ZCM?
1 19000 [5.6] 9600 [2.8]
35800 [10.5] 15 12
875 [413] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGJF-10?ZCM?
1 19000 [5.6] 9600 [2.8]
35600 [10.4] 14.5 12
875 [413] 71
2 24500 [7.2] 11100 [3.3] 1200 [566] 72
RGJF-12?RCM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15.1 12.5
875 [413] 71
2 24700 [7.2] 11100 [3.3] 1200 [566] 72
RGLE-07?BRQ?
1 18400 [5.4] 9800 [2.9]
35000 [10.3] 15.1 12.5
775 [366] 71
2 23200 [6.8] 11800 [3.5] 1025 [484] 72
RGLE-10?BRM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15.1 12.5
875 [413] 71
2 24700 [7.2] 11100 [3.3] 1200 [566] 72
RGLE-12?ARM?
1 19600 [5.7] 9400 [2.8]
36000 [10.5] 15.1 12.5
925 [437] 71
2 25000 [7.3] 11000 [3.2] 1225 [578] 72
RGPE-07?BRQ?
1 19600 [5.7] 9400 [2.8]
35800 [10.5] 15.1 12.5
900 [425] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGPE-10?BRM?
1 19600 [5.7] 9400 [2.8]
35800 [10.5] 15.1 12.5
900 [425] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
RGPE-12?ARM?
1 19200 [5.6] 9600 [2.8]
35800 [10.5] 15.1 12.5
875 [413] 71
2 24700 [7.2] 11100 [3.3] 1200 [566] 72
RGRM-07?YBG?
1 18800 [5.5] 9600 [2.8]
34800 [10.2] 14 11
850 [401] 71
2 23700 [6.9] 11100 [3.3] 1200 [566] 72
RGRM-09?ZAJ?
1 19400 [5.7] 9400 [2.8]
35400 [10.4] 14.5 11.5
950 [448] 71
2 24400 [7.1] 11000 [3.2] 1225 [578] 72
RGRM-10?ZAJ?
1 19000 [5.6] 9600 [2.8]
35000 [10.3] 14.5 12
875 [413] 71
2 23600 [6.9] 11400 [3.3] 1150 [543] 72
RGRM-12?RAJ?
1 19600 [5.7] 9400 [2.8]
35600 [10.4] 15 12
925 [437] 71
2 24600 [7.2] 11000 [3.2] 1225 [578] 72
RGTM-07?RBG?
1 18600 [5.4] 9800 [2.9]
35000 [10.3] 15 12.5
800 [378] 71
2 23300 [6.8] 11700 [3.4] 1050 [495] 72
RGTM-09?ZAJ?
1 19900 [5.8] 9300 [2.7]
35600 [10.4] 15 12
975 [460] 71
2 24600 [7.2] 11000 [3.2] 1225 [578] 72
RGTM-10?RBJ?
1 19900 [5.8] 9300 [2.7]
35800 [10.5] 15 12
975 [460] 71
2 24800 [7.3] 11000 [3.2] 1225 [578] 72
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling