Specification Sheet
Air
Performance Data
RARL- JEC Series
17
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEC
RCFN-H*3624
ROCA-070E03
1 21100 [6.2] 9100 [2.7]
37400 [11.0] 16 13
800 [378] 71
2 26300 [7.7] 11100 [3.3] 1000 [472] 72
ROCA-070E04
1 21100 [6.2] 9100 [2.7]
37400 [11.0] 16 13
800 [378] 71
2 26300 [7.7] 11100 [3.3] 1000 [472] 72
ROLA-070E03
1 22200 [6.5] 8600 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 27700 [8.1] 10300 [3.0] 1175 [554] 72
ROLA-070E04
1 22200 [6.5] 8600 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 27700 [8.1] 10300 [3.0] 1175 [554] 72
ROLA-115E05
1 22200 [6.5] 8600 [2.5]
38500 [11.3] 16.5 13
900 [425] 71
2 28300 [8.3] 10200 [3.0] 1200 [566] 72
RCFN-H*3624+RXMD-C06 Coil Only
1 21400 [6.3] 8600 [2.5]
37400 [11.0] 14 12
925 [437] 71
2 26900 [7.9] 10500 [3.1] 1125 [531] 72
RCQD-3621
RGFE-06?MCK?
1 19900 [5.8] 9100 [2.7]
36600 [10.7] 15.5 12.5
725 [342] 71
2 25600 [7.5] 11000 [3.2] 1000 [472] 72
RGFE-07?MCK?
1 19900 [5.8] 9100 [2.7]
36600 [10.7] 15.5 12.5
725 [342] 71
2 25700 [7.5] 10900 [3.2] 1025 [484] 72
RGFE-09?ZCM?
1 21200 [6.2] 8600 [2.5]
37600 [11.0] 15.5 12.5
875 [413] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGFE-10?ZCM?
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 15.5 12.5
900 [425] 71
2 27600 [8.1] 10000 [2.9] 1225 [578] 72
RGFG-06?MCK?
1 19900 [5.8] 9100 [2.7]
36600 [10.7] 15.5 12.5
725 [342] 71
2 25600 [7.5] 11000 [3.2] 1000 [472] 72
RGFG-07?MCK?
1 20500 [6.0] 8900 [2.6]
36400 [10.7] 15.5 12.5
800 [378] 71
2 25400 [7.4] 11000 [3.2] 1000 [472] 72
RGFG-09?ZCM?
1 21200 [6.2] 8600 [2.5]
37600 [11.0] 15.5 12.5
875 [413] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGFG-10?ZCM?
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 15.5 12.5
900 [425] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGJF-06?MCK?
1 21600 [6.3] 8400 [2.5]
37400 [11.0] 15.5 12.5
925 [437] 71
2 27300 [8.0] 10100 [3.0] 1200 [566] 72
RGJF-07?MCK?
1 20200 [5.9] 9000 [2.6]
36600 [10.7] 15.5 12.5
750 [354] 71
2 25700 [7.5] 10900 [3.2] 1025 [484] 72
RGJF-09?ZCM?
1 21200 [6.2] 8600 [2.5]
37800 [11.1] 15.5 12.5
875 [413] 71
2 27800 [8.1] 10000 [2.9] 1225 [578] 72
RGJF-10?ZCM?
1 21200 [6.2] 8600 [2.5]
37600 [11.0] 15.5 12.5
875 [413] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGPE-05?BMK?
1 21600 [6.3] 8400 [2.5]
37400 [11.0] 15.5 12
900 [425] 71
2 27300 [8.0] 10100 [3.0] 1200 [566] 72
RGPE-07?AMK?
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 15.5 12.5
900 [425] 71
2 27600 [8.1] 10000 [2.9] 1225 [578] 72
RGPE-07?BRQ?
1 21800 [6.4] 8400 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 28000 [8.2] 10000 [2.9] 1225 [578] 72
RGPE-10?BRM?
1 21800 [6.4] 8400 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 28000 [8.2] 10000 [2.9] 1225 [578] 72
RGRM-04?MAE?
1 20200 [5.9] 9000 [2.6]
36600 [10.7] 15.5 12.5
750 [354] 71
2 25700 [7.5] 10900 [3.2] 1025 [484] 72
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions