Specification Sheet

Air
Performance Data
RARL- JEC Series
19
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
038JEC
RCQD-3624
RGJF-10?ZCM?
1 21200 [6.2] 8600 [2.5]
37600 [11.0] 15.5 12.5
875 [413] 71
2 27500 [8.1] 10100 [3.0] 1200 [566] 72
RGJF-12?RCM?
1 21400 [6.3] 8600 [2.5]
37800 [11.1] 16 13
875 [413] 71
2 27700 [8.1] 10100 [3.0] 1200 [566] 72
RGPE-07?BRQ?
1 21800 [6.4] 8400 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 28000 [8.2] 10000 [2.9] 1225 [578] 72
RGPE-10?BRM?
1 21800 [6.4] 8400 [2.5]
38000 [11.1] 16 13
900 [425] 71
2 28000 [8.2] 10000 [2.9] 1225 [578] 72
RGPE-12?ARM?
1 21400 [6.3] 8600 [2.5]
37800 [11.1] 16 13
875 [413] 71
2 27700 [8.1] 10100 [3.0] 1200 [566] 72
RGRM-07?YBG?
1 20900 [6.1] 8700 [2.5]
37000 [10.8] 15 11.5
850 [401] 71
2 26900 [7.9] 10100 [3.0] 1200 [566] 72
RGRM-09?ZAJ?
1 21600 [6.3] 8400 [2.5]
37600 [11.0] 15.5 12.5
950 [448] 71
2 27600 [8.1] 10000 [2.9] 1225 [578] 72
RGRM-10?ZAJ?
1 21200 [6.2] 8600 [2.5]
37200 [10.9] 15.5 12.5
875 [413] 71
2 26800 [7.9] 10400 [3.0] 1150 [543] 72
RGRM-12?RAJ?
1 21800 [6.4] 8400 [2.5]
37800 [11.1] 16 12.5
925 [437] 71
2 27800 [8.1] 10000 [2.9] 1225 [578] 72
RGTM-07?RBG?
1 20500 [6.0] 8900 [2.6]
37000 [10.8] 15.5 13
800 [378] 71
2 26200 [7.7] 10800 [3.2] 1050 [495] 72
RGTM-09?ZAJ?
1 22100 [6.5] 8300 [2.4]
37800 [11.1] 15.5 12.5
975 [460] 71
2 27800 [8.1] 10000 [2.9] 1225 [578] 72
RGTM-10?RBJ?
1 22100 [6.5] 8300 [2.4]
38000 [11.1] 16 13
975 [460] 71
2 28000 [8.2] 10000 [2.9] 1225 [578] 72
ROCA-070E03
1 20500 [6.0] 8900 [2.6]
36800 [10.8] 15.5 13
800 [378] 71
2 25800 [7.6] 11000 [3.2] 1000 [472] 72
ROCA-070E04
1 20500 [6.0] 8900 [2.6]
36800 [10.8] 15.5 13
800 [378] 71
2 25800 [7.6] 11000 [3.2] 1000 [472] 72
ROLA-070E03
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 16 13
900 [425] 71
2 27400 [8.0] 10200 [3.0] 1175 [554] 72
ROLA-070E04
1 21800 [6.4] 8400 [2.5]
37600 [11.0] 16 13
900 [425] 71
2 27400 [8.0] 10200 [3.0] 1175 [554] 72
ROLA-115E05
1 21800 [6.4] 8400 [2.5]
37800 [11.1] 16 13
900 [425] 71
2 27700 [8.1] 10100 [3.0] 1200 [566] 72
RCQD-3624+RXMD-C06 Coil Only
1 21000 [6.2] 8400 [2.5]
36800 [10.8] 14 12
925 [437] 71
2 26400 [7.7] 10400 [3.0] 1125 [531] 72
RCSL-H*3621 RHPL-HM3621
1 19700 [5.8] 9100 [2.7]
35200 [10.3] 15 12
925 [437] 71
2 24400 [7.1] 10800 [3.2] 1225 [578] 72
RCSL-H*3821 RHPL-HM3821
1 19600 [5.7] 9400 [2.8]
35400 [10.4] 15 12
950 [448] 71
2 24000 [7.0] 11400 [3.3] 1150 [543] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling