Specification Sheet
Air
Performance Data
RARL- JEC Series
22
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
049JEC
RCFL-H*4824
RGTM-09?ZAJ?
1 24500 [7.2] 14000 [4.1]
44500 [13.0] 15 11.5
1100 [519] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RGTM-10?RBJ?
1 24600 [7.2] 13900 [4.1]
45000 [13.2] 15 11.5
1125 [531] 72
2 28900 [8.5] 16100 [4.7] 1425 [672] 72
ROCA-070E04
1 25000 [7.3] 13500 [4.0]
44500 [13.0] 14.5 11
1200 [566] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
ROLA-070E04
1 24800 [7.3] 13700 [4.0]
45000 [13.2] 15 11
1175 [554] 72
2 29900 [8.8] 15100 [4.4] 1600 [755] 72
ROLA-115E05
1 23800 [7.0] 14200 [4.2]
44500 [13.0] 15 11.5
1050 [495] 72
2 28200 [8.3] 16300 [4.8] 1400 [661] 72
RCFL-H*4824+RXMD-C06 Coil Only
1 25200 [7.4] 13300 [3.9]
45500 [13.3] 14 11
1250 [590] 72
2 30400 [8.9] 15100 [4.4] 1425 [672] 72
RCFN-H*4824
RGFE-09?ZCM?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16.5 12
1025 [484] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGFE-10?ZCM?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16.5 12
1025 [484] 72
2 34000 [10.0] 14500 [4.2] 1425 [672] 72
RGFE-12?RCM?
1 27700 [8.1] 13300 [3.9]
49000 [14.4] 16.5 12.5
1025 [484] 72
2 34700 [10.2] 14300 [4.2] 1450 [684] 72
RGFG-09?ZCM?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16.5 12
1025 [484] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGFG-10?ZCM?
1 27800 [8.1] 13200 [3.9]
48500 [14.2] 16 12
1050 [495] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGFG-12?RCM?
1 27700 [8.1] 13300 [3.9]
49000 [14.4] 16.5 12.5
1025 [484] 72
2 34700 [10.2] 14300 [4.2] 1450 [684] 72
RGGE-09?ZCM?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16.5 12.5
1025 [484] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGGE-10?ZCM?
1 27800 [8.1] 13200 [3.9]
48500 [14.2] 16.5 12
1050 [495] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGGE-12?RCM?
1 29600 [8.7] 12400 [3.6]
49500 [14.5] 16.5 12.5
1200 [566] 72
2 36200 [10.6] 13300 [3.9] 1575 [743] 72
RGJF-09?ZCM?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16.5 12.5
1025 [484] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGJF-10?ZCM?
1 27800 [8.1] 13200 [3.9]
48500 [14.2] 16.5 12
1050 [495] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGJF-12?RCM?
1 29600 [8.7] 12400 [3.6]
49500 [14.5] 16.5 12.5
1200 [566] 72
2 36200 [10.6] 13300 [3.9] 1575 [743] 72
RGLE-07?BRQ?
1 27700 [8.1] 13300 [3.9]
49000 [14.4] 16.5 12.5
1025 [484] 72
2 34400 [10.1] 14600 [4.3] 1400 [661] 72
RGLE-10?BRM?
1 27800 [8.1] 13200 [3.9]
49000 [14.4] 16.5 12.5
1050 [495] 72
2 34400 [10.1] 14600 [4.3] 1400 [661] 72
RGLE-12?ARM?
1 28500 [8.4] 13000 [3.8]
49000 [14.4] 16.5 12.5
1075 [507] 72
2 34500 [10.1] 14500 [4.2] 1425 [672] 72
RGPE-07?BRQ?
1 27800 [8.1] 13200 [3.9]
49000 [14.4] 16.5 12.5
1050 [495] 72
2 34400 [10.1] 14600 [4.3] 1400 [661] 72
RGPE-10?BRM?
1 28500 [8.4] 13000 [3.8]
49000 [14.4] 16.5 12.5
1075 [507] 72
2 34400 [10.1] 14600 [4.3] 1400 [661] 72
Rev.
5/8/2012
➀ Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard Conditions—Cooling