Specification Sheet

Air
Performance Data
RARL- JEC Series
23
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
049JEC
RCFN-H*4824
RGPE-12?ARM?
1 28500 [8.4] 13000 [3.8]
49000 [14.4] 16.5 12.5
1075 [507] 72
2 34500 [10.1] 14500 [4.2] 1425 [672] 72
RGRM-09?ZAJ?
1 28000 [8.2] 13000 [3.8]
49000 [14.4] 16 12
1075 [507] 72
2 34400 [10.1] 14600 [4.3] 1400 [661] 72
RGRM-10?ZAJ?
1 27700 [8.1] 13300 [3.9]
48500 [14.2] 16 12
1025 [484] 72
2 34000 [10.0] 14500 [4.2] 1425 [672] 72
RGRM-12?RAJ?
1 28000 [8.2] 13000 [3.8]
48500 [14.2] 16.5 12.5
1075 [507] 72
2 34000 [10.0] 14500 [4.2] 1425 [672] 72
RGTM-07?RBG?
1 28700 [8.4] 12800 [3.8]
48500 [14.2] 16.5 12.5
1125 [531] 72
2 34400 [10.1] 14100 [4.1] 1475 [696] 72
RGTM-09?ZAJ?
1 28600 [8.4] 12900 [3.8]
48500 [14.2] 16.5 12.5
1100 [519] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RGTM-10?RBJ?
1 28700 [8.4] 12800 [3.8]
49000 [14.4] 16.5 12.5
1125 [531] 72
2 34500 [10.1] 14500 [4.2] 1425 [672] 72
ROCA-070E04
1 29100 [8.5] 12400 [3.6]
48500 [14.2] 16 12
1200 [566] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
ROLA-070E04
1 29000 [8.5] 12500 [3.7]
49000 [14.4] 16 12
1175 [554] 72
2 35700 [10.5] 13300 [3.9] 1600 [755] 72
ROLA-115E05
1 27800 [8.1] 13200 [3.9]
48500 [14.2] 16.5 12.5
1050 [495] 72
2 33900 [9.9] 14600 [4.3] 1400 [661] 72
RCFN-H*4824+RXMD-C06 Coil Only
1 29400 [8.6] 12100 [3.5]
49000 [14.4] 15 12
1250 [590] 72
2 35700 [10.5] 13300 [3.9] 1600 [755] 72
RCQD-4821
RGFE-09?ZCM?
1 27000 [7.9] 12500 [3.7]
46500 [13.6] 16 11.5
1025 [484] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGFE-10?ZCM?
1 27000 [7.9] 12500 [3.7]
46500 [13.6] 15.5 11.5
1025 [484] 72
2 32800 [9.6] 13700 [4.0] 1425 [672] 72
RGFG-09?ZCM?
1 27000 [7.9] 12500 [3.7]
46500 [13.6] 16 11.5
1025 [484] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGFG-10?ZCM?
1 28900 [8.5] 11600 [3.4]
47500 [13.9] 15.5 11.5
1200 [566] 72
2 35300 [10.3] 12200 [3.6] 1650 [779] 72
RGJF-09?ZCM?
1 27000 [7.9] 12500 [3.7]
47000 [13.8] 16 12
1025 [484] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
RGJF-10?ZCM?
1 27600 [8.1] 12400 [3.6]
46500 [13.6] 16 12
1050 [495] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGPE-07?BRQ?
1 29600 [8.7] 11400 [3.3]
47500 [13.9] 16 12
1225 [578] 72
2 35000 [10.3] 12500 [3.7] 1600 [755] 72
RGPE-10?BRM?
1 29600 [8.7] 11400 [3.3]
47500 [13.9] 16 12
1225 [578] 72
2 35000 [10.3] 12500 [3.7] 1625 [767] 72
RGRM-09?ZAJ?
1 27700 [8.1] 12300 [3.6]
46500 [13.6] 15.5 11.5
1075 [507] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
RGRM-10?ZAJ?
1 27000 [7.9] 12500 [3.7]
46500 [13.6] 15.5 11.5
1025 [484] 72
2 32800 [9.6] 13700 [4.0] 1425 [672] 72
RGTM-07?RBG?
1 28000 [8.2] 12000 [3.5]
47000 [13.8] 16 12
1125 [531] 72
2 33600 [9.8] 13400 [3.9] 1475 [696] 72
RGTM-09?ZAJ?
1 27900 [8.2] 12100 [3.5]
47000 [13.8] 16 12
1100 [519] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling