Specification Sheet

Air
Performance Data
RARL- JEC Series
25
Outdoor
Unit
RARL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
Net
Sensible
BTU/H [kW]
Net
Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
ID Coil ID Air Mover
Total Capacity
BTU/H [kW]
SEER EER
049JEC
RCQD-4824
ROCA-070E04
1 28900 [8.5] 11600 [3.4]
46500 [13.6] 15.5 11.5
1200 [566] 72
2 32600 [9.6] 13900 [4.1] 1400 [661] 72
ROLA-070E04
1 28700 [8.4] 11800 [3.5]
47500 [13.9] 16 11.5
1175 [554] 72
2 35000 [10.3] 12500 [3.7] 1600 [755] 72
ROLA-115E05
1 27600 [8.1] 12400 [3.6]
47000 [13.8] 16 12
1050 [495] 72
2 33100 [9.7] 13900 [4.1] 1400 [661] 72
RCQD-4824+RXMD-C06 Coil Only
1 28600 [8.4] 11400 [3.3]
47500 [13.9] 14.5 11.5
1250 [590] 72
2 35000 [10.3] 12500 [3.7] 1600 [755] 72
RCSL-H*4824 RHPL-HM4824
1 26200 [7.7] 13300 [3.9]
46000 [13.5] 16 12
1250 [590] 72
2 30900 [9.1] 15100 [4.4] 1625 [767] 72
061JEC
RCSN-H*6024
RHPN-HM6024
1 34100 [10.0] 14900 [4.4]
59000 [17.3] 16 13
1325 [625] 76
2 42700 [12.5] 16300 [4.8] 1775 [838] 78
1 - dehumid 29000 [8.5] 12500 [3.7] 1050 [495]
2 - dehumid 39300 [11.5] 18200 [5.3] 1450 [684]
RCFL-H*6024
RGFE-09?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGFE-10?ZCM?
1 32400 [9.5] 15600 [4.6]
57000 [16.7] 16 12
1225 [578] 76
2 39200 [11.5] 17800 [5.2] 1600 [755] 78
RGFE-12?RCM?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39900 [11.7] 17600 [5.2] 1625 [767] 78
RGFG-09?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGFG-10?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 40100 [11.7] 17400 [5.1] 1650 [779] 78
RGFG-12?RCM?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39900 [11.7] 17600 [5.2] 1625 [767] 78
RGGE-09?ZCM?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGGE-10?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGGE-12?RCM?
1 34400 [10.1] 14600 [4.3]
58500 [17.1] 16 12
1375 [649] 76
2 42100 [12.3] 16400 [4.8] 1750 [826] 78
RGJF-09?ZCM?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12
1225 [578] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGJF-10?ZCM?
1 32300 [9.5] 15700 [4.6]
57500 [16.8] 16 12
1200 [566] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGJF-12?RCM?
1 34400 [10.1] 14600 [4.3]
58500 [17.1] 16 12
1375 [649] 76
2 42100 [12.3] 16400 [4.8] 1750 [826] 78
RGLE-07?BRQ?
1 32900 [9.6] 15600 [4.6]
57500 [16.8] 16 12.5
1225 [578] 76
2 39700 [11.6] 17800 [5.2] 1600 [755] 78
RGLE-10?BRM?
1 32800 [9.6] 15700 [4.6]
58000 [17.0] 16 12.5
1200 [566] 76
2 40200 [11.8] 17800 [5.2] 1600 [755] 78
RGLE-12?ARM?
1 32900 [9.6] 15600 [4.6]
58000 [17.0] 16 12.5
1225 [578] 76
2 40200 [11.8] 17800 [5.2] 1600 [755] 78
RGPE-07?BRQ?
1 32900 [9.6] 15600 [4.6]
58000 [17.0] 16 12.5
1225 [578] 76
2 40200 [11.8] 17800 [5.2] 1600 [755] 78
Rev.
5/8/2012
Highest sales volume tested combination required by D.O.E. test procedures. [ ] Designates Metric Conversions
Performance Data @ AHRI Standard ConditionsCooling