Specification Sheet

10
Air
Performance Data
RPRL Series
Performance Data AHRI Standard Conditions
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Outdoor
Unit
RPRL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Heating Performance (70°F [21°C] Indoor)
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
Outdoor Air
17°F [-8.5°C] DB/
15°F [-9.5°C] WB
AHRI Rating
DOE
Region IV
HSPF
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
47°F [8.5°C] DB/
43°F [6°C] WB
17°F [-8.5°C] DB/
15°F [-9.5°C] WB
ID Coil ID Air Mover
Total
Capacity
SEER EER BTU/H [kW] COP BTU/H [kW] COP BTU/H [kW] BTU/H [kW]
037JEC
RCFL-H*3824
RGFG-12?RCM?
1 20600 [6.0] 8600 [2.5]
36200 [10.6] 16.5 12.5
875 [413] 69 24000 [7.0]
3.75
12700 [3.7]
2.55 34400 [10.1] 21600 [6.3] 9
2 26900 [7.9] 9300 [2.7] 1225 [578] 73 34400 [10.1] 21600 [6.3]
RGGE-09?ZCM?
1 21700 [6.4] 8100 [2.4]
36400 [10.7] 16 12
1025 [484] 69 24200 [7.1]
3.7
12900 [3.8]
2.5 34600 [10.1] 21800 [6.4] 9
2 27300 [8.0] 9100 [2.7] 1250 [590] 73 34600 [10.1] 21800 [6.4]
RGGE-10?ZCM?
1 20600 [6.0] 8600 [2.5]
36200 [10.6] 16 12
875 [413] 69 24000 [7.0]
3.7
12700 [3.7]
2.55 34600 [10.1] 21800 [6.4] 9
2 26900 [7.9] 9300 [2.7] 1200 [566] 73 34600 [10.1] 21800 [6.4]
RGGE-12?RCM?
1 20600 [6.0] 8600 [2.5]
36400 [10.7] 16.5 12.5
875 [413] 69 24000 [7.0]
3.8
12600 [3.7]
2.55 34400 [10.1] 21600 [6.3] 9
2 27100 [7.9] 9300 [2.7] 1200 [566] 73 34400 [10.1] 21600 [6.3]
RGJF-09?ZCM?
1 21700 [6.4] 8100 [2.4]
36400 [10.7] 16 12
1025 [484] 69 24200 [7.1]
3.7
12900 [3.8]
2.5 34600 [10.1] 21800 [6.4] 9
2 27300 [8.0] 9100 [2.7] 1250 [590] 73 34600 [10.1] 21800 [6.4]
RGJF-10?ZCM?
1 20600 [6.0] 8600 [2.5]
36200 [10.6] 16 12
875 [413] 69 24000 [7.0]
3.75
12700 [3.7]
2.55 34600 [10.1] 21800 [6.4] 9
2 26900 [7.9] 9300 [2.7] 1200 [566] 73 34600 [10.1] 21800 [6.4]
RGJF-12?RCM?
1 20600 [6.0] 8600 [2.5]
36400 [10.7] 16.5 12.5
875 [413] 69 24000 [7.0]
3.8
12600 [3.7]
2.55 34400 [10.1] 21600 [6.3] 9
2 27100 [7.9] 9300 [2.7] 1200 [566] 73 34400 [10.1] 21600 [6.3]
RGLE-07?BRQ?
1 20600 [6.0] 8600 [2.5]
36400 [10.7] 16.5 12.5
925 [437] 69 24000 [7.0]
3.75
12700 [3.7]
2.55 34400 [10.1] 21600 [6.3] 9
2 27100 [7.9] 9300 [2.7] 1225 [578] 73 34400 [10.1] 21600 [6.3]
RGLE-10?BRM?
1 20800 [6.1] 8600 [2.5]
36400 [10.7] 16.5 12.5
875 [413] 69 23800 [7.0]
3.8
12600 [3.7]
2.55 34400 [10.1] 21400 [6.3] 9
2 27100 [7.9] 9300 [2.7] 1200 [566] 73 34400 [10.1] 21400 [6.3]
RGLE-12?ARM?
1 20600 [6.0] 8600 [2.5]
36400 [10.7] 16.5 12.5
925 [437] 69 24000 [7.0]
3.8
12600 [3.7]
2.55 34400 [10.1] 21400 [6.3] 9
2 27100 [7.9] 9300 [2.7] 1225 [578] 73 34400 [10.1] 21400 [6.3]
RGLR-12?ARM?
1 21600 [6.3] 8200 [2.4]
36400 [10.7] 16.5 12.5
1000 [472] 69 24000 [7.0]
3.8
12700 [3.7]
2.55 34400 [10.1] 21600 [6.3] 9
2 27100 [7.9] 9300 [2.7] 1225 [578] 73 34400 [10.1] 21600 [6.3]
RGPE-07?BRQ?
1 20600 [6.0] 8600 [2.5]
36400 [10.7] 16.5 12.5
900 [425] 69 24000 [7.0]
3.75
12700 [3.7]
2.55 34400 [10.1] 21600 [6.3] 9
2 27100 [7.9] 9300 [2.7] 1225 [578] 73 34400 [10.1] 21600 [6.3]
RGPE-10?BRM?
1 20600 [6.0] 8600 [2.5]
36400 [10.7] 16.5 12.5
900 [425] 69 24000 [7.0]
3.8
12700 [3.7]
2.55 34400 [10.1] 21600 [6.3] 9
2 27100 [7.9] 9300 [2.7] 1225 [578] 73 34400 [10.1] 21600 [6.3]
RGPE-12?ARM?
1 20600 [6.0] 8600 [2.5]
36400 [10.7] 16.5 12.5
875 [413] 69 24000 [7.0]
3.8
12700 [3.7]
2.55 34400 [10.1] 21400 [6.3] 9
2 27100 [7.9] 9300 [2.7] 1200 [566] 73 34400 [10.1] 21400 [6.3]
RGPR-12?ARM?
1 21600 [6.3] 8200 [2.4]
36600 [10.7] 16.5 12.5
1000 [472] 69 24000 [7.0]
3.75
12800 [3.8]
2.55 34400 [10.1] 21600 [6.3] 9
2 27500 [8.1] 9100 [2.7] 1250 [590] 73 34400 [10.1] 21600 [6.3]
RGRM-07?YBG?
1 20100 [5.9] 8700 [2.5]
35600 [10.4] 15.5 11.5
850 [401] 69 24200 [7.1]
3.55
12900 [3.8]
2.4 35200 [10.3] 22400 [6.6] 8.5
2 26300 [7.7] 9300 [2.7] 1200 [566] 73 35200 [10.3] 22400 [6.6]
RGRM-09?RAJ?
1 21700 [6.4] 8100 [2.4]
36600 [10.7] 16 12
1050 [495] 69 24200 [7.1]
3.7
12900 [3.8]
2.5 34800 [10.2] 21800 [6.4] 9
2 27900 [8.2] 8700 [2.5] 1325 [625] 73 34800 [10.2] 21800 [6.4]
Rev.
4/25/2012
Highest sales volume tested combination required by DOE test procedures.
[ ] Designates Metric Conversions