Specification Sheet
Air
Performance Data
RPRL Series
5
Performance Data AHRI Standard Conditions
Note: Only these combinations of indoor/outdoor units are approved and any other combinations should not be used.
Outdoor
Unit
RPRL-
Model Numbers
Stage
AHRI Cooling Performance
80°F [26.5°C] / 67°F [19.5°C] WB Indoor Air
95°F [35°C] DB Outdoor Air
AHRI Heating Performance (70°F [21°C] Indoor)
Outdoor Air
47°F [8.5°C] DB/
43°F [6°C] WB
Outdoor Air
17°F [-8.5°C] DB/
15°F [-9.5°C] WB
AHRI Rating
DOE
Region IV
HSPF
Net Sensible
BTU/H [kW]
Net Latent
BTU/H [kW]
AHRI Ratings
Indoor Airflow
CFM [L/s]
Sound
Rating
dB
47°F [8.5°C] DB/
43°F [6°C] WB
17°F [-8.5°C] DB/
15°F [-9.5°C] WB
ID Coil ID Air Mover
Total
Capacity
SEER EER BTU/H [kW] COP BTU/H [kW] COP BTU/H [kW] BTU/H [kW]
025JEC
RCSL-H*2621 ➀
RHPL-HM2421
1 14700 [4.3] 6300 [1.8]
25400 [7.4] 17 13
600 [283] 67 0 [0.0]
3.94
0 [0.0]
2.6 22600 [6.6] 14000 [4.1] 9
2 18500 [5.4] 6900 [2.0] 775 [366] 70 22600 [6.6] 14000 [4.1]
1 - dehumid 12500 [3.7] 5100 [1.5] 525 [248]
2 - dehumid 16800 [4.9] 7400 [2.2] 650 [307]
RCFL-H*2617
RGFE-07?MCK?
1 14600 [4.3] 6300 [1.8]
25400 [7.4] 17 13
600 [283] 67 16600 [4.9]
3.86
9300 [2.7]
2.16 22800 [6.7] 14100 [4.1] 8.5
2 18800 [5.5] 6700 [2.0] 825 [389] 70 22800 [6.7] 14100 [4.1]
RGFG-06?MCK?
1 14600 [4.3] 6300 [1.8]
25200 [7.4] 17 13
575 [271] 67 16600 [4.9]
3.86
9300 [2.7]
2.16 22800 [6.7] 14100 [4.1] 8.5
2 18300 [5.4] 6900 [2.0] 800 [378] 70 22800 [6.7] 14100 [4.1]
RGFG-07?MCK?
1 14500 [4.2] 6300 [1.8]
25600 [7.5] 17 13
600 [283] 67 16600 [4.9]
3.84
9300 [2.7]
2.16 22800 [6.7] 14200 [4.2] 8.5
2 18900 [5.5] 6600 [1.9] 850 [401] 70 22800 [6.7] 14200 [4.2]
RGGE-06?MCK?
1 14600 [4.3] 6300 [1.8]
25600 [7.5] 17 13
625 [295] 67 16600 [4.9]
3.88
9200 [2.7]
2.16 22800 [6.7] 14100 [4.1] 8.5
2 18800 [5.5] 6700 [2.0] 825 [389] 70 22800 [6.7] 14100 [4.1]
RGGE-07?MCK?
1 14600 [4.3] 6300 [1.8]
25200 [7.4] 17 13
575 [271] 67 16600 [4.9]
3.88
9200 [2.7]
2.16 22800 [6.7] 14100 [4.1] 8.5
2 18400 [5.4] 6900 [2.0] 800 [378] 70 22800 [6.7] 14100 [4.1]
RGJF-06?MCK?
1 14600 [4.3] 6300 [1.8]
25600 [7.5] 17 13
625 [295] 67 16600 [4.9]
3.88
9200 [2.7]
2.16 22800 [6.7] 14100 [4.1] 8.5
2 18800 [5.5] 6700 [2.0] 825 [389] 70 22800 [6.7] 14100 [4.1]
RGJF-07?MCK?
1 14600 [4.3] 6300 [1.8]
25200 [7.4] 17 13
575 [271] 67 16600 [4.9]
3.88
9200 [2.7]
2.16 22800 [6.7] 14100 [4.1] 8.5
2 18400 [5.4] 6900 [2.0] 800 [378] 70 22800 [6.7] 14100 [4.1]
RGLE-07?AMK?
1 14600 [4.3] 6300 [1.8]
25200 [7.4] 17 13
600 [283] 67 16600 [4.9]
3.9
9200 [2.7]
2.16 22600 [6.6] 14000 [4.1] 8.5
2 18400 [5.4] 6900 [2.0] 800 [378] 70 22600 [6.6] 14000 [4.1]
RGPE-05?BMK?
1 14600 [4.3] 6300 [1.8]
25200 [7.4] 17 13
575 [271] 67 16600 [4.9]
3.88
9300 [2.7]
2.16 22600 [6.6] 14100 [4.1] 8.5
2 18400 [5.4] 6900 [2.0] 800 [378] 70 22600 [6.6] 14100 [4.1]
RGPE-07?AMK?
1 14600 [4.3] 6300 [1.8]
25600 [7.5] 17 13
625 [295] 67 16600 [4.9]
3.9
9200 [2.7]
2.16 22600 [6.6] 14000 [4.1] 8.5
2 18800 [5.5] 6700 [2.0] 825 [389] 70 22600 [6.6] 14000 [4.1]
RGRM-04?MAE?
1 14600 [4.3] 6300 [1.8]
25200 [7.4] 17 13
575 [271] 67 16600 [4.9]
3.82
9300 [2.7]
2.14 22800 [6.7] 14200 [4.2] 8.5
2 18300 [5.4] 6900 [2.0] 800 [378] 70 22800 [6.7] 14200 [4.2]
RGRM-06?MAE?
1 14600 [4.3] 6300 [1.8]
25400 [7.4] 17 13
600 [283] 67 16600 [4.9]
3.84
9300 [2.7]
2.16 22800 [6.7] 14200 [4.2] 8.5
2 18700 [5.5] 6700 [2.0] 825 [389] 70 22800 [6.7] 14200 [4.2]
RGRM-07?MAE?
1 14500 [4.2] 6300 [1.8]
25400 [7.4] 17 13
625 [295] 67 16700 [4.9]
3.78
9300 [2.7]
2.14 23000 [6.7] 14300 [4.2] 8.5
2 18800 [5.5] 6600 [1.9] 850 [401] 70 23000 [6.7] 14300 [4.2]
RGTM-06?MAE?
1 15600 [4.6] 6100 [1.8]
25400 [7.4] 17 13
750 [354] 67 16700 [4.9]
3.86
9400 [2.8]
2.12 22800 [6.7] 14100 [4.1] 8.5
2 18800 [5.5] 6700 [2.0] 825 [389] 70 22800 [6.7] 14100 [4.1]
ROCA-070E03
1 14600 [4.3] 6300 [1.8]
25200 [7.4] 17 13
600 [283] 67 16600 [4.9]
3.9
9200 [2.7]
2.16 22600 [6.6] 14000 [4.1] 8.5
2 18400 [5.4] 6900 [2.0] 800 [378] 70 22600 [6.6] 14000 [4.1]
Rev.
4/25/2012
➀ Highest sales volume tested combination required by DOE test procedures.
[ ] Designates Metric Conversions