Technical data

REGULAR CARE
11
TEMPERATURE LIMITING VALVE
A RheemPlus water heater is fitted with a temperature limiting valve at the hot
w
ater outlet. The valve is set to deliver water not exceeding 50°C.
The valve should be checked for performance every twelve months. This can
be performed by measurin
g the water temperature from a hot tap with a
thermometer. If the water is being delivered at a temperature exceeding 50°C,
phone your nearest Rheem Service Department or Accredited Service Agent to
arrange for an inspection.
The valve should be replaced at intervals not exceeding 5 years, or more
frequently in areas w
here there is a high incidence of water deposits (refer to
“Water Supplies” on page 33). Failure to do this may result in water at a
temperature up to 70°
C being delivered at the hot tap, increasing the risk of
scald injury.
EXPANSION CONTROL VALVE
In many areas, including South Australia, Western Australia and scaling water
areas, an ex
pansion control valve is fitted to the cold water line to the water
heater. The expansion control valve may discharge a small quantity of water
from its drain line during the heating period instead of the temperature pressure
relief valve on the water heater.
Operate the easing lever on the expansion control valve once every six
months. It is
very important you raise and lower the lever gently. The
expansion control valve should be checked for performance or replaced at
intervals not exceeding 5 years, or more frequently in areas where there is a
high incidence of water deposits.