Specifications
INSTALLATION – SOLAR STORAGE TANK
30
TYPICAL INSTALLATION – TANK MOUNTED GAS BOOSTER 20L
SOLAR PREHEAT
(HOT WATER) OUTLET
Use a union connection
& insulate hot water pipe.
FRONT
COVER
SOLAR CIRCUIT
PRESSURE RELIEF VALVE
AND DRAIN LINE
CABLE TIE
MOUNT
CABLE TIE
TO PIPE INSULATION
GAS BOOSTER
WATER HEATER
FLUE OUTLET
Clearances must
comply with AS 5601
TEMPERATURE
PRESSURE
RELIEF VALVE
(on right hand side
of tank)
POWER SUPPLY CORD
All electrical work must
be carried out by a
licensed tradesperson.
Power outlet must be
earthed & weatherproof.
SOLAR MONITOR
WATER HEATER SUPPORT
As specified in AS/NZS 3500.4
POWER SUPPLY CORD
All electrical work must be carried
out by a licenced tradesperson.
Power outlet must be earthed &
weatherproof.
COLD WATER
CONNECTION
Cold water connection
must comply with local
regulations.
SOLAR PREHEAT
INLET
Use a union connection
& insulate pipe.
HOT WATER OUTLET
Use a union connection
& insulate hot water pipe.
INSULATED HOT
WATER PIPE
GAS SUPPLY PIPE
Isolating valve &
union must be used.
SOLAR COLD PIPE
Insulated copper
pipe.Use a
compression
nut and olive.
HOT SENSOR LEAD
SENSOR
CONNECTION
SOLAR HOT PIPE
Insulated copper pipe.
Use a compression
nut and olive.
TPR VALVE DRAIN LINE
Drainline must terminate
away from the base of the
water heater. Discharge
point must comply with
AS/NZS 3500.4
OUTDOOR INSTALLATION
SOLAR CLOSED CIRCUIT with INTERGRATED
GAS BOOST VSi160 WATER HEATER
SK6545
08/08 REV_BD
Solar VSi Indirect (Outdoor Tank Location) Water Heater
with Tank Mounted In-Series 20L Gas Booster