Specifications
COMMISSIONING
51
11. Mark the dynamic level of the closed circuit fluid in the
hose on the side of the solar storage tank with a non
permanent marker when satisfied the solar circuit
circulation is operating satisfactorily.
12. If the procedure to check the solar circuit circulation is
not complete before the pump has automatically turned
off, then:
switch off the electrical supply at the power outlet to
the solar storage tank.
recommence this procedure from step 9.
Drain Back Function
13. Switch off the electrical supply at the power outlet to the solar storage tank.
The red LED on the solar monitor label will stop flashing.
The pump will deactivate.
The closed circuit fluid will drain back down to the heat exchanger and the level of the closed circuit fluid
in the clear hose will rise.
Wait three (3) minutes to allow the drain back of the closed circuit fluid in the solar circuit.
14. Note the level of the closed circuit fluid in the fluid level hose.
The closed circuit fluid should drain back to the original static level.
If the closed circuit fluid does not drain back completely to this level, then check:
there is a continuous fall of at least 5° (1 in 10 grade) in the solar pipe work from the solar collector
to the solar storage tank.
the solar collector has an inclination of not less than 10°.
(refer to “Solar Collector Location” on page 33)
the connectors on the inlet and outlet of the collector are orientated downwards to ensure complete
drain back of the closed circuit fluid from the solar collector.
If necessary, rectify the:
solar pipe work if there is either insufficient fall or not a continuous fall in the pipe work.
solar collector inclination if it is less than 10°.
orientation of the connectors downwards if they are not orientated correctly.
Recheck the drain back function of the solar circuit by repeating step 7 and recommencing this
procedure from step 9.
mark dynamic
level on tank