Operating instructions

59
CONNECTIONS – ELECTRICAL
All electrical work and permanent wiring must be carried out by a qualified person and in accordance with the
Wiring Rules AS/NZS 3000 and all local codes and regulatory authority requirements.
Warning: Temperature controllers must not be fitted to this water heater (871 series) if it is installed as
an in-series gas booster with a solar water heater system or if a Water Star water heater is installed because
water at a temperature much higher than the controller setting can be delivered. If a solar or Water Star
water heater has been installed to an existing water heater installation, then all controllers must be
disconnected and removed.
The water heater is supplied with a 1.8 metre lead and plug and requires a weatherproof 240 V 50 Hz
general purpose outlet (GPO) to be located within 1.2 metres of the installation. The GPO must be clear of
the flue exhaust, draining water, gas supply pipe and water connections.
The power consumption of the water heater is:
Component
Power
consumption
Comments
Gas water heater
62 Watts
64 Watts
66 Watts
022, 024, M24 – Burner on, anti frost device inactive
026 – Burner on, anti frost device inactive
018, 020 – Burner on, anti frost device inactive
150 Watts Burner on, anti frost device active
The water heater will only operate on a sine wave at 50 Hz. Devices generating a square wave cannot be
used to supply power to the water heater.