Specifications

TM031 Integrity 18, 20, 24, 26L Service Instructions REV: B
D.O.I: February 2008
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
29
Diagnostic Test Points
Refer to wiring diagram, page 5, for connector and wiring positions.
Test
Point
Measuring Point
Normal Condition
Items Under Test
Connector
Wire Nº
& colour
1
A
R1 R2
AC 85V 120V
Main Power
2
B
W8 W12
50 kilo-ohms 500 kilo-ohms
Overheat Limiter
3
B
BR9 BL10
DC 2V 5V(Pulse) *1
Water Flow Sensor pulse signal
More than 1310 pulse/min
R11 BL10
DC 7V 15V
Water Flow Sensor
4
K
B4 W6
DC 120V 170V
Fan Motor
R3 B4
DC 11V 19V
Y1 B4
DC 4V 10V(Pulse) *1
Fan Motor is pulse signal
More than 4800 pulse/min
5
B
Y6 BL7
@ 20ºC 10.3 kilo-ohms
Water Inlet Thermistor
@ 40ºC 4.9 kilo-ohms
6
B
W5 BL7
@ 20ºC 10.3 kilo-ohms
Heat Exchanger Thermistor
@ 40ºC 4.9 kilo-ohms
7
B
R4 BL7
@ 20ºC 10.3 kilo-ohms
Hot Water Outlet Thermistor
@ 40ºC 4.9 kilo-ohms
8
B
B3 BL7
@ 25ºC 5.0 kilo-ohms
Ambient Air Thermistor
@ 5ºC 12.7 kilo-ohms
9
J
R1 Earth
AC 2V 20V *2
Flame Sensor detecting flame
W3 Earth
AC 2V 20V *2
B2 - Earth
AC 2V 20V *2
10
B
R1 BL2
DC 1.5V 8.0V
Proportional Gas Flow Regulating
42 ohms 97 ohms
11
L
Y9 BL10
DC 70V 110V
Gas Inlet Solenoid Valve
0.8 kilo-ohms 2.2 kilo-ohms
12
L
R2 R8
AC 85V 120V
Igniter
13
L
R3 BL10
DC 70V 110V
Solenoid Valve 1
0.8 kilo-ohms 2.2 kilo-ohms
14
L
W4 BL10
DC 70V 110V
Solenoid Valve 2
0.8 kilo-ohms 2.2 kilo-ohms
15
L
B5 BL10
DC 70V 110V
Solenoid Valve 3
0.8 kilo-ohms 2.2 kilo-ohms
16
J
R1 Earth
AC 2V 20V *2
Flame Sensor not detecting flame.
W3 - Earth
AC 2V 20V *2
17
J
B2 - Earth
AC 2V 20V *2
18
H
W2 BL8
DC 8V 16V
Water Volume Control Motor
position switch
R7 BL8
DC 8V 16V
GR6 BL8
Less than DC 1V (Limiter off)
DC 4V 6V (Limiter on)
19
L
O6 O12
DC 70 110V
0.6 kilo-ohms 2.8 kilo-ohms
Water Bypass Solenoid (models
with -B or -C suffix in model number
only e.g. 871024-B)
NOTES:
*1: Approximate reading measured by digital multimeter on DC range.
*2: Approximate reading measured by digital multimeter on AC range.