Fault Finding Chart 1
Voltages up to 240 volts will be present within the water heater, take care
not to touch wiring terminals. Use an insulated tool when operating the DIP
switch or MIN and MAX buttons.
Power Supply
Is 240
volts AC Present at
the power
point?
NO
No power supply. Check
household wiring.
YES
Test 1
Cordset open circuit? - replace.
Inline fuses open circuit replace.
Internal wiring from terminal block
or transformer open circuit
repair.
NO
YES
Test 2
Transformer failed replace.NO
Test 3
Power filter open circuit replace.NO
Test 4
YES
Error code
Displayed?
Remote controller failed
replace.
Remote controller cable open
circuit replace.
YES
PCB failed replace.NO
1
Is
240 volts
AC Present at the
transformers primary
winding?
Is
The transformers
output voltage 90 - 110
volts AC?
Is
90 - 110 volts AC
Present at the
PCB?
Turn DIP
switch 1 on.