Specifications

TM002 Integrity 18 & 20L Service Instructions REV: E
D.O.I: 7/11/2007
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled
41
Fault Finding Tests 23 – 28
Test 23 - Diagnostic Point 18 Test 24 - Diagnostic Point 18
Conduct test with water flowing
Conduct test with water flowing
Test Point
Connector H
Measured Value
Test Point
Connector H
Measured Value
2 White - 8 Black DC8 – 16V 7 Red - 8 Black DC8 – 16V
Components will be “Live” when conducting tests, exercise caution
Test 25 - Diagnostic Point 18 Test 28 - Diagnostic Point 3
Test Point
Connector H
Measured Value
6 Green - 8 Black
On position < DC1V
Off position DC4 – 6V
Conduct test with water flowing
Measure the voltage between 11 Red and 10
Black on connector B.
Voltage should be between DC7 – 15V