Fault Finding Chart 3.8
Fan current detecting
circuit failure
3.8
NO
2
Replace the PCB assembly.
Note: only replace the PCB
assembly if error code 79 is
displayed during combustion.
Was
Error code 79
displayed prior to
opening the hot
tap?
YES
Error code
79 displayed.
Fault Finding Tests 29 – 31
Test 29 - Diagnostic Point 3
Components will be “Live”
when conducting tests,
exercise caution
Conduct test with water flowing
Measure the voltage between 9 Brown
and 10 Black on connector B.
Voltage should be between DC2 – 5V
Test 30 and 31 - Diagnostic Point 19
Test 30
Isolate power when
conducting resistance test
Unplug connector L from the PCB and
measure the resistance between 6
Orange and 12 Orange.
Resistance should be between 0.6kilo-
ohms and 2.8kilo-ohms
.
Test 31
Components will be “Live”
when conducting tests,
exercise caution
Conduct test with water flowing
Measure the voltage between 6 Orange
and 12 Orange on connector L.
Voltage should be between DC70 –
110V