Specifications

TM002 Integrity 18 & 20L Service Instructions REV: E
D.O.I: 7/11/2007
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled
47
Fault Finding Tests 32 and 33
Components will be “Live” when
conducting test, exercise caution
Test 32
Conduct test with water flowing
Measure the voltage at the 3 pin connector located
between the water flow sensor and the comparator.
Measure the voltage between the brown and black
wires at this connector.
Voltage should be between DC2 – 5V.
Isolate power when removing flow
turbine
Test 33
Remove flow sensor turbine by following
component replacement procedure 21 on page
53.
The flow sensor turbine should spin freely. Check
for wear or blockage by foreign material such as
thread tape.
Burner Gas Pressure Check
Voltages up to 240 volts will be present within the water heater, take care
not to touch wiring terminals. Use an insulated tool when operating the DIP
switch or MIN and MAX buttons.
Minimum Burner Gas Pressure
1. Remove the front panel from the water
heater.
2. Remove burner test point screw and fit
manometer.
3. Turn on the remote controller (If fitted).
4. Open a hot tap slowly, to achieve the
minimum flow rate at which the burners
will ignite.
5. Press and hold the MIN button (“1L” is
displayed on the LED) and observe the
reading on the manometer.
6. Release the MIN button. If the reading
observed in step 5 agrees with the rating
label, no further adjustment is required.
Maximum Burner Gas Pressure
7. Open the hot tap fully to achieve
maximum flow rate.
8. Press and hold the MAX button (“3H” is
displayed on the LED) and observe the
reading on the manometer.
9. Release the MAX button. If the reading
observed in step 8 agrees with the rating
label, no further adjustment is required.
10. Turn the hot tap off.
11. Remove manometer and refit the burner
test point screw ensuring the seal is gas
tight.
12. Refit the front panel to the water heater.