Specifications
TM002 Integrity 18 & 20L Service Instructions REV: E
D.O.I: 7/11/2007
This document is stored and maintained electronically by Service. All printed copies not bearing this statement in RED are deemed “uncontrolled”
54
6. Remove 2 Philips head retaining screws holding flow sensor to water body assembly
and remove flow sensor.
7. Using a flat bladed screwdriver lever the metal disc and o-ring from flow sensor
housing on water body assembly. Lever the disc out by placing the shaft of the
screwdriver across the disc with the tip of the screwdriver on the far inside edge of the
disc.
8. Remove the four screws from the cold water inlet connector and withdraw the
connector and o-ring from the base of the water heater.
9. Gently withdraw flow sensor turbine out from water inlet of water body assembly using
a pair of long nose pliers.
10. Reassemble in reverse order of above ensuring open slot on turbine is centred and
facing towards the face of the flow sensor.
Power cord: (Procedure 22)
1. Switch off power at power point and unplug power cord from power point.
2. Unscrew screw on power inlet cover and remove power inlet cover.
3. Undo cord clamp screw located next to power filter and remove clamp.
4. Disconnect the power cable wiring loom plug and withdraw power cable through slot in
heater jacket.
5. Reassemble in reverse order of above.