User Manual
Table Of Contents
- Contents
- About Your Water Heater
- Water Heater Application
- Model Type
- Mains Pressure
- Water Heater Operation
- Reduced Hot Water Flow When Heat Exchanger Is Cold
- Gas Boosting For A Solar Water Heater
- How Hot Should The Water Be?
- Hotter Water Increases The Risk Of Scald Injury
- Safety
- Warnings
- Precautions
- General Maintenance
- Minor Maintenance Every Six Months
- Major Service Every Five Years
- Circulated Hot Water Flow And Return System
- Going On Holidays
- To Turn Off The Water Heater
- To Turn On The Water Heater
- Frost Protection
- Draining The Water Heater
- How Do I Know If The Water Heater Is Installed Correctly?
- Victorian Customers
- Does The Water Chemistry Affect The Water Heater?
- How Long Will The Water Heater Last?
- Temperature Control
- Temperature Control – Standard
- Temperature Control – Deluxe
- Deluxe Controller Functions
- Deluxe Controller
- Voice Prompt And Operating Tone
- Assistance Call Function
- Temperature Settings – Deluxe Controllers
- Temperature Adjustment – Deluxe Controllers
- Kitchen Controller – Deluxe
- Bathroom Controllers – Deluxe
- Bath Fill Function
- Bath Fill Function – Brief Guide
- Bath Fill Function – Explanatory Notes
- Turning Off Bath Fill Function During Its Operation
- Notes on the Bath Fill function:
- Opening a Second Hot Water Tap During Bath Fill Operation
- Early Completion of Bath Fill Operation
- Interrupting Bath Fill Operation
- Operation of the Bath Fill function whilst a Deluxe Controller has priority
- Water Supplies
- Save A Service Call
- No Display On The Controller
- Cold Water From The Hot Tap
- Water Is Too Hot Or Not Hot Enough
- Reduced Hot Water Flow When Heat Exchanger Is Cold
- No Water From The Hot Tap
- Water Flow Fluctuates
- Gas Booster Operating Too Frequently
- Fan Continues To Run After Water Heater Operation Stops
- Clouds Of White ‘Vapour’ From The Flue Terminal
- Pressure Relief Valve Discharging
- Error Code
- Higher Than Expected Gas Bills
- Installation – Water Heater
- Installation Standards
- Water Heater Application
- Water Heater Location
- Installation Within A Covered Area
- Pipe Cover
- Recess Installation
- Frost Protection
- Mains Water Supply
- Hot Water Delivery
- Circulated Hot Water Flow And Return System
- Reducing Heat Losses
- Water Temperature Diagrams
- Technical Data
- Dimensions – Water Heater
- Dimensions – Standard Controllers
- Dimensions – Deluxe Controllers
- Typical Installation – Outdoor Location
- Connections – Plumbing
- Connections – Electrical
- EZ LINK System Dual Installation
- Installation – Controllers
- Commissioning
- Draining The Water Heater
- Rheem Continuous Flow Gas Water Heater Warranty – Australia and New Zealand Only
- 1. The Rheem Warranty – General
- 2. Terms Of The Rheem Warranty And Exclusions To It
- 3. What Is Covered By The Rheem Warranty For The Water Heaters Detailed In This Document
- 4. Entitlement To Make A Claim Under This Warranty
- 5. How To Make A Claim Under This Warranty
- 6. The Australian Consumer Law

ABOUT YOUR WATER HEATER
6
HOTTER WATER INCREASES THE RISK OF SCALD INJURY
This water heater can deliver water at temperatures which can cause scalding. Check the water temperature
before use, such as when entering a shower or filling a bath or basin, to ensure it is suitable for the application
and will not cause scald injury.
We recommend and it may be required by regulations that an approved temperature limiting device be fitted
into the hot water piping to the bathroom and ensuite when an 874 series water heater is installed. This will
keep the water temperature below 50°C – AU or 55°C – NZ at the bathroom and ensuite. The risk of scald
injury will be reduced and if no controllers are installed and the preset outlet temperature setting has not been
adjusted below 55°C or if a Kitchen controller is installed, still allow hotter water to the kitchen and laundry.
An 876 series water heater will not deliver temperatures exceeding 50°C, in accordance with AS 3498. There
is no need to fit a temperature limiting device to satisfy the requirements of AS/NZS 3500.4, if an 876 series
water heater is installed in an application where 50°C is the maximum permissible hot water temperature at
the outlet of a sanitary fixture used primarily for personal hygiene purposes.
SAFETY
This water heater is supplied with temperature sensors, a FlameSafe
®
protection system and a pressure relief
valve. These devices must not be tampered with or removed. The water heater must not be operated unless
each of these devices is fitted and is in working order.
If the power supply cord or plug is damaged, it must be replaced by a qualified person in order to avoid a
hazard. The power supply cord and plug must be replaced with a genuine replacement part available from
Rheem. Phone Rheem Service or their nearest Accredited Service Agent / Centre to arrange for an inspection.
The Rheem warranty may not cover faults if relief valves or other safety devices are tampered with or
if the installation is not in accordance with these instructions.
WARNINGS
This water heater is only intended to be operated by persons who have the experience or the knowledge
and the capabilities to do so.
This water heater is not intended to be operated by persons with reduced physical, sensory or mental
capabilities i.e. the infirm, or by children. Children should be supervised to ensure they do not interfere
with the water heater.
The water heater uses 240 Volt AC electrical power for operation of the control systems and the
combustion fan. The removal of the front panel will expose 240 V wiring. It must only be removed by a
qualified person.
The power lead from the water heater must be plugged into a weatherproof electrical outlet. Take care
not to touch the power plug with wet hands.
For continued safety of this water heater it must be installed, operated and maintained in accordance with
the Owner’s Guide and Installation Instructions.
Do not modify this water heater.
Do not use or store flammable materials in or near this water heater.
Flammable liquids (such as petrol), combustible materials (such as
newspapers) and similar articles must be kept well away from the water heater
and the flue terminal.
Do not spray aerosols in the vicinity of this water heater while it is in operation.
Gases from some aerosol sprays become corrosive when drawn into a flame.
Do not store swimming pool chemicals, household cleaners, etc., near the
water heater.
Do not place articles on or against this water heater, or in contact with the flue
terminal. Ensure the flue terminal is not obstructed in any way at any time.
Do not use Propane / Butane gas mixtures in a Propane model. A Propane model is designed to operate
on Propane only. The use of Propane / Butane mixture, such as automotive LP gas fuel, in a Propane
model is unsafe and can cause damage to the water heater.
Note: LP gas models sold in New Zealand are designed to operate on the Propane / Butane mixture
supplied in New Zealand. An LP gas model has an LFZ suffix in its model number.