Specification Sheet

Air
Gross Systems Performance Data
RGEA14 Series
41
GROSS SYSTEMS PERFORMANCE DATA—RGEA14060A
ENTERING INDOOR AIR @ 80°F [26.7°C] dbE
wbE 71°F [21.7°C] 67°F [19.4°C] 63°F [17.2°C]
CFM [L/s]
1870 [883] 1700 [802] 1440 [680] 1870 [883] 1700 [802] 1440 [680] 1870 [883] 1700 [802] 1440 [680]
DR
0.14 0.13 0.11 0.14 0.13 0.11 0.14 0.13 0.11
O
U
T
D
O
O
R
D
R
Y
B
U
L
B
T
E
M
P
E
R
A
T
U
R
E
°F
[°C]
75
[23.9]
Total BTUH [kW]
Sens BTUH [kW]
Power
72.1 [21.1]
40.6 [11.9]
3.5
70.8 [20.7]
38.8 [11.4]
3.5
68.8 [20.2]
36.0 [10.6]
3.5
67.8 [19.9]
47.8 [14.0]
3.5
66.6 [19.5]
45.7 [13.4]
3.5
64.7 [19.0]
42.4 [12.4]
3.4
63.6 [18.6]
54.4 [16.0]
3.5
62.4 [18.3]
52.0 [15.2]
3.5
60.7 [17.8]
48.3 [14.2]
3.4
80
[26.7]
Total BTUH [kW]
Sens BTUH [kW]
Power
70.3 [20.6]
39.6 [11.6]
3.7
69.0 [20.2]
37.8 [11.1]
3.7
67.1 [19.7]
35.1 [10.3]
3.7
66.0 [19.3]
46.7 [13.7]
3.7
64.8 [19.0]
44.7 [13.1]
3.7
63.0 [18.5]
41.5 [12.2]
3.6
61.8 [18.1]
53.4 [15.6]
3.7
60.7 [17.8]
51.0 [15.0]
3.6
59.0 [17.3]
47.4 [13.9]
3.6
85
[29.4]
Total BTUH [kW]
Sens BTUH [kW]
Power
68.4 [20.0]
38.5 [11.3]
4.0
67.1 [19.7]
36.8 [10.8]
3.9
65.3 [19.1]
34.1 [10.0]
3.9
64.1 [18.8]
45.7 [13.4]
3.9
62.9 [18.4]
43.6 [12.8]
3.9
61.2 [17.9]
40.5 [11.9]
3.8
59.9 [17.5]
52.3 [15.3]
3.9
58.8 [17.2]
50.0 [14.6]
3.9
57.2 [16.7]
46.4 [13.6]
3.8
90
[32.2]
Total BTUH [kW]
Sens BTUH [kW]
Power
66.4 [19.5]
37.3 [10.9]
4.2
65.2 [19.1]
35.7 [10.5]
4.1
63.4 [18.6]
33.1 [9.7]
4.1
62.1 [18.2]
44.5 [13.1]
4.2
61.0 [17.9]
42.6 [12.5]
4.1
59.3 [17.4]
39.5 [11.6]
4.1
57.9 [17.0]
51.2 [15.0]
4.1
56.8 [16.7]
48.9 [14.3]
4.1
55.3 [16.2]
45.4 [13.3]
4.0
95
[35]
Total BTUH [kW]
Sens BTUH [kW]
Power
64.3 [18.8]
36.2 [10.6]
4.4
63.2 [18.5]
34.6 [10.1]
4.4
61.4 [18.0]
32.1 [9.4]
4.3
60.0 [17.6]
43.4 [12.7]
4.4
58.9 [17.3]
41.4 [12.1]
4.4
57.3 [16.8]
38.5 [11.3]
4.3
55.8 [16.4]
50.0 [14.7]
4.4
54.8 [16.1]
47.8 [14.0]
4.3
53.3 [15.6]
44.4 [13.0]
4.3
100
[37.8]
Total BTUH [kW]
Sens BTUH [kW]
Power
62.1 [18.2]
35.0 [10.3]
4.7
61.0 [17.9]
33.4 [9.8]
4.7
59.3 [17.4]
31.0 [9.1]
4.6
57.9 [17.0]
42.2 [12.4]
4.7
56.8 [16.7]
40.3 [11.8]
4.6
55.2 [16.2]
37.4 [11.0]
4.6
53.6 [15.7]
48.8 [14.3]
4.7
52.7 [15.4]
46.7 [13.7]
4.6
51.2 [15.0]
43.3 [12.7]
4.5
105
[40.6]
Total BTUH [kW]
Sens BTUH [kW]
Power
59.9 [17.5]
33.8 [9.9]
5.0
58.8 [17.2]
32.3 [9.5]
5.0
57.2 [16.8]
30.0 [8.8]
4.9
55.6 [16.3]
41.0 [12.0]
5.0
54.6 [16.0]
39.1 [11.5]
4.9
53.1 [15.6]
36.3 [10.6]
4.9
51.4 [15.1]
47.6 [14.0]
4.9
50.5 [14.8]
45.5 [13.3]
4.9
49.1 [14.4]
42.2 [12.4]
4.8
110
[43.3]
Total BTUH [kW]
Sens BTUH [kW]
Power
57.6 [16.9]
32.5 [9.5]
5.3
56.5 [16.6]
31.0 [9.1]
5.3
55.0 [16.1]
28.8 [8.4]
5.2
53.3 [15.6]
39.7 [11.6]
5.3
52.3 [15.3]
37.9 [11.1]
5.2
50.9 [14.9]
35.2 [10.3]
5.2
49.0 [14.4]
46.3 [13.6]
5.2
48.2 [14.1]
44.3 [13.0]
5.2
46.8 [13.7]
41.1 [12.0]
5.1
115
[46.1]
Total BTUH [kW]
Sens BTUH [kW]
Power
55.1 [16.2]
31.2 [9.1]
5.6
54.1 [15.9]
29.8 [8.7]
5.6
52.6 [15.4]
27.7 [8.1]
5.5
50.8 [14.9]
38.4 [11.2]
5.6
49.9 [14.6]
36.7 [10.7]
5.5
48.5 [14.2]
34.0 [10.0]
5.5
46.6 [13.7]
45.0 [13.2]
5.6
45.8 [13.4]
43.0 [12.6]
5.5
44.5 [13.0]
40.0 [11.7]
5.4
120
[48.9]
Total BTUH [kW]
Sens BTUH [kW]
Power
52.6 [15.4]
29.8 [8.7]
6.0
51.7 [15.1]
28.5 [8.4]
5.9
50.2 [14.7]
26.5 [7.8]
5.8
48.3 [14.2]
37.0 [10.8]
5.9
47.5 [13.9]
35.4 [10.4]
5.9
46.1 [13.5]
32.8 [9.6]
5.8
44.1 [12.9]
43.7 [12.8]
5.9
43.3 [12.7]
41.7 [12.2]
5.9
42.1 [12.3]
38.8 [11.4]
5.8
125
[51.7]
Total BTUH [kW]
Sens BTUH [kW]
Power
50.0 [14.7]
28.5 [8.3]
6.3
49.1 [14.4]
27.2 [8.0]
6.3
47.8 [14.0]
25.2 [7.4]
6.2
45.7 [13.4]
35.6 [10.4]
6.3
44.9 [13.2]
34.1 [10.0]
6.2
43.7 [12.8]
31.6 [9.3]
6.2
41.5 [12.2]
41.5 [12.2]
6.3
40.8 [11.9]
40.4 [11.8]
6.2
39.6 [11.6]
37.5 [11.0]
6.1
DR —Depression ratio
dbE —Entering air dry bulb
wbE—Entering air wet bulb
Total —Total capacity x 1000 BTUH
Sens —Sensible capacity x 1000 BTUH
Power —KW input
NOTES: When the entering air dry bulb is other than 80°F [27°C], adjust the sensible
capacity from the table by adding [1.10 x CFM x (1 – DR) x (dbE – 80)].
[ ] Designates Metric Conversions