Sales Fact Sheet

SALES FACT SHEET
Rheem Heating, Cooling and Water Heating FORM NO. A11-217-SFS
P.O. Box 17010, Fort Smith, AR 72917 PRINTED IN U.S.A. QG 10-12
RAPM- JAZ SERIES
Efficiencies up to 16.00 SEER/13.55 EER
Nominal Sizes 1.5 to 5 Tons
[5.28 kW] to [17.6 kW]
Cooling Capacities
18.8 to 62.5 kBTU
[5.50 kW] to [18.32 kW]
GENERAL TERMS OF LIMITED WARRANTY
Rheem will furnish a replacement for any part of this product which fails in
normal use and service within the applicable period stated, in accordance
with the terms of the limited warranty.
Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ten (10) Years
Conditional Parts (Registration Required) . . . . . . . . . . . . . . . . .Ten (10) Years
Rheem
Classic
®
Series
Air Conditioners
Features
Attractive, louvered wrap-around jacket protects the coil from yard haz-
ards and weather extremes. Top grille is steel reinforced for extra strength.
Cabinet is powder painted for all-weather protection.
Air is discharged upward away from bushes and shrubs. The discharge
pattern of the top grille provides minimum air restriction.
Combination Grille/Motor Mount secures the motor to the underside of the
discharge grille. The grille protects the motor windings and bearings from
rain and snow.
All controls are accessible by removing one service panel. Removable top
grille provides access to the condenser fan motor and condenser coil.
Single speed 8-pole fan motor designed for low speed, quiet, energy-
saving operation.
All models meet or exceed a 1000-hour salt spray test per ASTM B117
Standard Practice for Operating Salt Spray Testing Apparatus.
MODEL
Nominal Cooling
Capacity (BTU/HR)
VOLTAGE
PHASE
HEIGHT
WIDTH
LENGTH
Shipping
Weight
Service
Valve -
Liquid
Service
Valve -
Suction
PRICE
018JAZ
024JAZ
030JAZ
036JAZ
042JAZ
048JAZ
056JAZ
060JAZ
18,000
24,000
30,000
36,000
42,000
48,000
56,000
60,000
208/230
208/230
208/230
208/230
208/230
208/230
208/230
208/230
1
1
1
1
1
1
1
1
19"
29"
29"
33"
33"
33"
33"
33"
27 - 5/8"
31 - 1/2"
31 - 1/2"
31 - 1/2"
31 - 1/2"
31 - 1/2"
31 - 1/2"
31 - 1/2"
40 - 1/2"
44 - 3/8"
44 - 3/8"
44 - 3/8"
44 - 3/8"
44 - 3/8"
44 - 3/8"
44 - 3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/8"
3/4"
3/4"
3/4"
7/8"
7/8"
7/8"
7/8"
7/8"
160.5
214.5
214
227
256
298
306.5
306.5
“Proper sizing and installation of equipment is critical to achieve optimal performance. Split system air conditioners and heat pumps must be matched
with appropriate coil components to meet ENERGY STAR criteria. Ask your Contractor for details or visit www.energystar.gov.”

Summary of content (2 pages)