TO PLACE WATER HEATER IN OPERATION:
Make certain tank is completely filled with water before
placing the water heater in operation. (Refer to Installation
Section of this manual)
1. WATER TEMPERATURE SETTING — To comply with
safety regulations and reduce the risk of scald injury,
the thermostat(s) of the water heater has been set at
the factory to a setting corresponding to 120° F. (49°C)
This is the preferred starting point for setting the con-
trol for general purpose hot water. To meet commer-
cial water needs, the Booster model’s thermostat is
adjustable to 190° F (88°C) to insure the 180° (82°C) F
minimum for dishwasher rinse applications and other
commercial purposes.
Water temperatures over 125°F (52°C) can cause severe
burns instantly or death from scalds.
Safety and energy conservation are factors to be
considered when setting the water temperature on the
thermostat. The most energy efficient operation will
result when the temperature setting is the lowest that
satisfies the needs consistent with the application.
There is a hot water SCALD POTENTIAL if the thermostat
is set too high.
NOTE: When this water heater is supplying general pur-
pose hot water requirements for use by individuals, a
thermostatically controlled mixing valve for reducing
point of use water temperature is recommended to re-
duce the risk of scald injury. Contact a licensed plumber
or the local plumbing authority for further information.
Outlet water temperatures will vary during normaloper-
ating cycles. Reliable temperature readings should be
taken shortly after the thermostat(s) cycle off during a
period of little or no use.
If water temperature other than 120° F (49°C) is need-
ed, the following instructions will apply depending on
model.
SURFACE MOUNTED THERMOSTAT MODELS:
Be certain power to the water heater is turned OFF be-
fore adjusting temperature setting of thermostat.
A. Do turn off power to water heater if it has been
subjected to over heating, fire, flood or physical dam-
age.
B. DO NOT turn on water heater unless it is filled with
water.
C. DO NOT turn on water heater if cold water supply
shut-off valve is closed.
D.If there is any difficulty in understanding or follow-
ing the OPERATION or MAINTENANCE instructions,
it is recommended that a qualified person or service-
man perform the work.
Hydrogen gas can be produced in a hot water sys-
tem served by this water heater that has not been
used for a long period of time (generally two weeks
or more).
HYDROGEN GAS IS EXTREMELY FLAMMABLE!! To-
dissipate such gas and to reduce risk of injury, it
isrecommended that the hot water faucet be opened
for several minutes at the kitchen sink before using
any electrical appliance connected to the hot water-
system. If hydrogen is present, there will probably
be an unusual sound such as air escaping through
the pipe as the water begins to flow. Do not smoke
or use an open flame near the faucet at the time it is
open.
SAFETY PRECAUTIONS
CAUTION
!
Operation
R
E
S
E
T
R
E
S
E
T
TURN OFF
POWER
BEFORE
SERVICING
LOW
MED
HI
To adjust the water temperature on Surface Mounted
Thermostat models, insert a small straight screw-
driver into slotted screw of indicator and move indi-
cator to desired setting.See Operation Section of this
Manual for details.
CAUTION!! — Hotter water increases the risk of
SCALDING!
Surface Mounted
Thermostat
Figure 4. — Thermostat Adjustment
CAUTION
!
DANGER
!
DANGER
!
To adjust the water temperature on Im-
mersion Thermostat models,turn thermo-
stat dial to align desired mark with index
line above thermostat. See Operation
Section of this Manual for details.
Immersion Thermostat
°F
1
9
0
°
1
7
0
°
1
5
0
°
1
4
0
°
1
3
0
°
1
2
0
°
1
1
0
°
V
E
R
Y
H
O
T
W
A
R
M
E-10 Model Only
WA RNING
!