Instructions / Assembly

42
Venting for Direct-Vent Water Heater (cont.)
Horizontal Vent Installation (cont.)
Using a thick bead of high temperature silicone,
seal the overlapping area of the outer 5-in. (12.7-
cm) pipe.
Attach required vent sections between the water
heater collar and the horizontal vent termination.
Typical Horizontal Termination with
1/4 In. Per Foot of DOWNWARD Slope
!
CAUTION:
The condensate collector must be used in
horizontal terminations if vertical rise in the vent
system exceeds 2 feet (610 mm).*
NOTICES:
Maintain the proper clearance between the
vent pipe and combustible or noncombustible
materials as described on page 29.
A zero clearance of 0 in. (0 cm) is allowed
between the air intake pipes and combustible
material.
Use proper support for the vent and air intake
pipes as described on page 34.
Support method used should isolate the
vent pipe from floor joists or other structural
members. This helps prevent transmission of
noise and vibration.
DO NOT support, pin, or secure the venting
system in a way that restricts the normal
thermal expansion and contraction of the
chosen venting material.
3
Vent Pipe Wall Plate
Inspection
Access Panel
(Optional)
Inspection
Access Panel
(Optional)
Ceiling Fire
Stop
2' max.*
(610 mm)
1/4" Per Foot Downward Slope
90˚
Elbow
INSTALLATION INSTRUCTIONS
Venting