Instructions / Assembly

29
INSTALLATION INSTRUCTIONS
General
Every vent or air intake pipe penetration of a floor or
ceiling should be sealed.
Failure to install and properly vent the water heater to
the outdoors as outlined on pages 34 through 46 can
result in unsafe operation.
Long hot water lines should be insulated to conserve
water and energy.
The water heater and water lines should be protected
from exposure to freezing temperatures.
Minimum water heater clearances from combustible
and noncombustible construction are as follows:
– 1/2 in. (1.3 cm) for sides
– 0 in. (0 cm) for rear with support bracket(s)
– 12 in. (30 cm) from the bottom, top, and front
– 0 in. (0 cm) for vent or air intake pipe
NOTICE:
Preferred maintenance clearance is 24 in. (61 cm)
from top, bottom, and front of unit.
12" min.
(300 mm)
12" min.
(300 mm)
1/2" min.
(13 mm)
12" min.
(300 mm)
0"
(0 mm)
0" min.
(0 mm)
Sealing Plate
DO NOT install the water heater in areas
prohibited by National Fuel Gas Code in
U.S. installation or CAN/CSA B149.1 in
Canadian installation.
DO NOT install the water heater where it
is subject to vibrations.
DO NOT install the water heater in a
recreational vehicle, mobile home, boat,
or other watercraft.
DO NOT install the water heater near
vents for heating and cooling unless
a minimum clearance of 4 ft (1.2 m) is
maintained.
Choosing a Location (cont.)